1. SPECIFICATIONS

User capacity:
Relays:

Output:
Entry mode:
RFID reading type:
Reading distance:
Power supply:
Buzzer, backlight control:
Tamper:
RS-485 interface:

Door Open Time:
IP Factor:
Operating Temperature:
Operating Humidity: 
Firmware upgrade:
Wiegand output:
Programming:
Door operation:
Holidays:
Event capacity:

100 fingerprints and 100 Cards
1 or 2 depending on the remote relay unit
1 with RTT and RU1 and 2 with RU2 and DINRTT 

RS-485, Wiegand
Fingerprint, Card, Fingerprint or Card
EM 4002/4100 and HID (125kHz) 
up to 4cm
12 VDC; max. 100mA
Yes, ON/OFF via XPR Smart Admin
Yes
Yes, for connecting I/O boards like
RU1, RTT, RU2, DINRTT
0 to 255 sec. or toggle (ON/OFF mode)
IP65
-20°C to +50°C
5% to 95% RH without condensation
Yes, via 

Bluetooth® 

wireless technology

Wiegand 24, 26, 32, 34, 56, 58 bits
via XPR Smart Admin
via XPR Smart Access
24
4000

1

 2. MOUNTING

4.

1.

Cable

Ø6.0(3NoS)

3

0

m

m

5mm

2.

  3 (3 x 30mm)

3.

  1 (M3 x 6mm)

MC-MINI

Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MC-MINI metal cover available in our accessories in order to protect 
the sensor from direct rainfall. The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the 
temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a 
third  party  sealed  wall  mount  box  (fitted  with  additional  heater  if  very  low  temperature)  to  keep  a  constant  sensor  level  performance.  XPR™  cannot 
guarantee the functionality of the product if measures and advice before are not followed. 
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use 
different readers depending on users.

3.0 RESET READER TO DEFAULT

1. Turn the device OFF
2. Put dipswitch 1 to position ON
3. Turn the power ON
4. Wait approx. 15 seconds until continuos beeps.
5. Put dipswitch 1 to OFF
6. Wait for long beep.

The reset procedure will bring the reader to default. The 
password will be deleted, all the users and the reader will be 
unpaired from the remote relay unit.

Unpairing the reader after reset, prevents unauthorized 
reset and keeps the unit in high security state.

Important note:

The 

Bluetooth

 reader comes with RU1 remote relay 

®

unit.
Make sure to make firmware update with the latest 
available firmware.

51mm

92mm

27mm

v.b8

ON

1

2

R

eset

Service mode