GW0017 User Manual
4
The description of indicators of GW0017-128S
Indicator
Definition
Status
Description
PWR
Power
Indicator
On
Power supply is normal .
Off
There is no power supply or power supply
is abnormal.
RUN
Running
Indicator
Slow Flashing
The device is running properly
Fast Flashing
SIP account is registered successfully.
On dull
The device is running improperly.
FXS 0~7
Telephone
In-use
Indicator
On
FXS port is currently occupied by a call
Off
FXS port is idle or faulty
LAN Port
(GE0/GE1)
Link (Green)
Flashing
The gateway is properly connected to
network
Off
The gateway is not connected to network
or network connection is improper
1.4
Features & Functions
➢
Key Features
⚫
High density gateway, up to 128 FXS
⚫
Modularized design, easy to expand
⚫
Support IPv4 and IPv6
⚫
5KM Maximum Cabling Length
⚫
Multiple codecs: G.711A/U,G.723.1,G.729A/B, iLBC
⚫
Fully compatible with leading IMS/NGN, SIP based IP telephony system
➢
Physical Interfaces
⚫
Capacity
Range from 8 to 128 FXS