background image

I worked really hard 
on this manual - 
so please read it...

XOU

24

BWDDGO

PANEL READY FRENCH DOOR COMBO

Содержание XOU24BWDDGO

Страница 1: ...I worked really hard on this manual so please read it XOU24BWDDGO PANEL READY FRENCH DOOR COMBO ...

Страница 2: ...priority service for your xo product Or by phone 973 403 8900 CONGRATULATIONS on purchasing your XO Before you proceed take just a moment to register your XO at www xoappliance com register your product REGISTRATION HELPS YOU BY Ensuring warranty coverage should you need service Providing ownership veri cation for insurance purposes XO can notify you in the event of product changes or recalls Or s...

Страница 3: ... For Service Warranty 4 7 Installation Instructions Sizes and Installation Dimensions Leveling Your XO 8 13 20 21 22 23 3 where things are please read and follow all safety instructions It s for your own good Honest Installer Checklist Find Your Model Operating Instructions Control System Overview Setting the Temperature Functions Wine and Beverage Storage Shelf Instructions 14 19 Integrated Panel...

Страница 4: ...nspected the stainless steel surfaces for any imperfections Have you reviewed this manual with the customer and explained the unit s operation and care Has the customer received copies of the literature and keys Have you properly disposed of all packing materials properly recycle please Is the customer satisfied O O O O O O O O O O O O After installation does the door open sufficiently to fully ex...

Страница 5: ...5 XOU24BWDDGO 2 these are the model covered in this book record your serial number here in case you need it later BEVERAGE CENTER WINE COOLER COMBO ...

Страница 6: ... to follow this step may cause problems Location Your XO unit should be located away from direct sunlight and heat sources stove heaters etc which may increase electrical consumption High or low ambient temperature may cause units to work improperly The floor must be strong enough to support your XO unit fully loaded Your XO unit must not be installed in areas of where water or excessive moisture ...

Страница 7: ...moving your XO unit to avoid damage to the electrical cord If the electrical cord of your XO unit becomes worn or damaged it must be replaced immediately by a qualified technician NEVER unplug your unit by pulling on the cord Unplug by gripping the plug firmly and pull out straight from the outlet INDOOR USE ONLY XO Refrigerators wine cellars and beverage centers described in this manual are rated...

Страница 8: ...NTER UNITS ARRIVE PRE WIRED WITH LOW PROFILE PLUGS FOR EASY INSTALLATION 4 7 35 1 4 MAX 34 1 8 MIN 24 90 Door Swing WALL Clearance Gap IF THE DOOR CAN T OPEN FULLY YOU CAN T PULL THE SHELVES OUT WHEN INSTALLING WITH THE HINGE SIDE NEXT TO A WALL LEAVE ADEQUITE SPACE FOR CABINET HANDLES DOOR MUST BE ABLE TO OPEN A MINIMUM OF 90 o THE DOOR STOP IS SET AT 110 BUT CAN BE REST TO 90 OR 140 IF NEEDED o ...

Страница 9: ...S WITH OVERLAY DOORS depth D CUSTOM OVERLAY PANELS MAY ADD UP TO 3 4 IN OVERALL DEPTH YOUR CHOICE OF CABINET HANDLES WILL ALSO ADD DEPTH 23 7 8 WIDE W DOOR MUST BE ABLE TO OPEN 90 MINIMUM TO ALLOW SHELVES AND RACKS TO EXTEND WITH THE DOOR OPEN AT 90 THE UNIT HAS A DEPTH OF 37 5 16 O O 23 3 4 including 3 4 panel TOP VIEW ...

Страница 10: ... in diameter and 1 2 deep into the top and bottom of the frame in the location shown 9 16 in from the edge and 7 16 out from the unfinished side facing the door TO ACCOMMODATE THE HINGE PINS ON THE HINGE SIDE OF THE PANEL CUTAWAY DETAIL Showing pin in hole 11 5 8 295 5MM 3 1 4 82 5mm min 2 7 8 73mm min IF FRAME HEIGHT EXCEEDS 30 ADDITIONAL STEPS ARE REQUIRED CONSULT XO 29 3 4 756mm min 30 762mm ma...

Страница 11: ...rewdriver install one screw into each of the ten holes and hand tighten flush with the frame DO NOT OVER TIGHTEN AS SCREWS MAY STRIP OUT 3 Before the frame has been mounted to the door attach your handle hardware at the height of your choosing drill counter sunk screw holes to align with your handle to help ensure the panel lies flat 6 ...

Страница 12: ...venly seated and flat 11 Reassemble the door back onto the hinges ADJUSTMENT SCREWS TOP BOTTOM If the door requires adjustment the top and bottom hinge each have adjustmet screws Loosen the screws then with the door open raise the handle side to level and re tighten the screws The door hinge stop is set at 110 Whille the door is off you can change it to either 90 or 140 Simply change the position o...

Страница 13: ...rners until all four legs are seated firmly on the floor and the interior floor of the unit is level both front to back and side to side Failure to follow this important step may cause problems with proper door operation excessive condensation vibration and noise 13 it s like zen but cooler get your level out ...

Страница 14: ...NDENT COOLING FANS INDEPENDENT CARBON ELEMENTS TWO GLIDING GLASS SHELVES SIX GLIDING WINE RACKS INDIVIDUAL DOOR LOCKS FRONT COOLING VENTS LEVELING LEGS XOU24BWDDGO COMBO BEVERAGE CENTER WINE COOLER INDIVIDUAL CONTROL PANELS ...

Страница 15: ... view the real time temperature press and hold the button for 5 seconds The interior temperature will flash in the LED Display for 5 seconds If you wish to change the display from Fahrenheit to Celsius or vice versa press and hold both and simultaneously for 5 seconds led lights L1 When you turn on your combo unit the internal light will switch on when the door is opened and off when the door is c...

Страница 16: ...ance will still operate However it will not respond to your actions While in the Sabbath Mode you may notice the fan running when the door is opened however this is not a result of your actions The compressor and fan will operate at predetermined times ress again ECO mode is turned off and it returns to standard mode Press for 5 seconds DEMO mode is turned on Press for 5 seconds again DEMO mode is...

Страница 17: ... 3 Seconds to turn OFF Press to Silence Alarm Light Function Button Toggle Between 3 Light Functions L1 L2 L3 TEMPERATURE DISPLAY Indicator Light Cooling Mode ON Press to raise temperature Press to lower temperature Changes interior light color Toggles between different operating modes 17 single zone control combo beverage center wine coolers 54 F is usually ideal for wine storage ...

Страница 18: ...ns TOTAL 49 Cans 12 oz size Store wine in sealed bottles only Avoid overloading Storing little or no product can cause excessive condensation 18 how many The capacity of your Wine Cooler Side is per Rack 3 Bordeaux Bottles 750ml of Racks x 6 Racks Bottom 3 Bordeaux Bottles 750ml TOTAL 21 Bordeaux Bottles 750ml ...

Страница 19: ...e the shelf STEP 2 Remove and re position the shelf glides STEP 3 Reverse the steps LIFT THE FRONT PULL OUT STRAIGHT SHELF GLIDE Install the right and left SHELF GLIDES in their new position by pushing the pins into the slots and click the front of the glide down to secure Replace the shelf ALL SHELVES MUST BE PUSHED ALL THE WAY IN BEFORE CLOSING THE DOOR DOOR MUST BE FULLY OPENED BEFORE PULLING S...

Страница 20: ... the wine cooler power failure Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If the power is off for a longer period of time you need to take the proper steps to protect your contents vacation Short vacations Leave the XO unit operating during vacations of less than three 3 weeks L...

Страница 21: ...l straight out to remove Align the tabs and insert the new filter Rotate filter 1 4 turn to lock in place Your Air Refresh Charcoal Filter I P N XOUAIRFILTER s Located Here 21 a breathe of fresh air for best results change every 3 to 6 months ...

Страница 22: ...you have not recently added a large quantity of warm bottles it may be a mechanical issue Unplug the unit and call for service The alarm is beeping and LO is displayed on the control panel This may be a sensor malfunction Unplug the unit and call for service Why does condensation form on the inside or outside of my XO unit It may be that the door is either opened repeatedly or not closed completel...

Страница 23: ...me obligations other than those expressly covered by this warranty Open box factory seconds scratch and dent floor models and commercial applications are excluded from these warranties Consumer shall be responsible for labor and transportation costs where noted above NO CONSEQUENTIAL DAMAGES XO is not responsible for economic loss profit loss or special indirect or consequential damages including ...

Страница 24: ...XO APPLIANCE 24 EISENHOWER PARKWAY ROSELAND NJ 07068 P 973 403 8900 WWW XOAPPLIANCE COM ...

Отзывы: