background image

XM1630S Software Reference Manual 

 

No. XM1630S-A00-104 

xmodus swiss GmbH 

2 / 32 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
Information provided by xmodus swiss GmbH is believed to be accurate and reliable. 
However, no responsibility is assumed by xmodus swiss for its use, nor any 
infringement of patents or other rights of third parties which may result from its use. 
No license is granted by implication or otherwise under any patent rights of xmodus 
other than for circuitry embodied in xmodus products. Xmodus swiss reserves the 
right to change circuitry at any time without notice. This document is subject to 
change without notice. 

 
 
Product names or services listed in this publication are for identification purposes 
only, and may be trademarks or registered trademarks of their respective companies. 
All other marks mentioned herein are the property of their respective owners. 
 
 
 
© 2009 xmodus swiss GmbH 
Printed in Switzerland 
All Rights Reserved  
 

Содержание XM1630S

Страница 1: ...XM1630S Software Reference Manual No XM1630S A00 104 xmodus swiss GmbH 1 32 LAN Modem XM1630S Software Reference Manual Version 104 Released 4 January 2010...

Страница 2: ...ication or otherwise under any patent rights of xmodus other than for circuitry embodied in xmodus products Xmodus swiss reserves the right to change circuitry at any time without notice This document...

Страница 3: ...based LAN configuration 8 3 2 Web based serial configuration 9 3 3 Web based statistics 10 3 4 Web based I O configuration 11 3 5 Web based administration 12 4 COMMAND LINE INTERFACE 13 4 1 Syntax an...

Страница 4: ...d and homologated and conforms to the CE regulations This gives fastest time to market to LAN enable any devices The compact size and high level of integration of the Socket Modem minimizes real estat...

Страница 5: ...ime use the default IP address of the modem 192 168 1 3 At the login prompt type ADMIN At the password prompt type AL6000S The user name and password are case sensitive 2 2 Login with Telnet Client Wh...

Страница 6: ...default serial configuration of the module 115200 bps 8 bit no parity 1 stop bit No authentication needed for TTY configuration Press 3 x Enter to arrive at the login prompt 2 4 General information T...

Страница 7: ...uration and monitoring through any common web browser When using your web browser to configure your LAN modem for the first time use the default IP address of the modem 192 168 1 3 At the login prompt...

Страница 8: ...figuration must be validated within 3 minutes by reconnecting via the Browser and clicking on the Modify validate settings button After this timeout with no validation the module returns to the previo...

Страница 9: ...s default received data is sent after 350 bytes buffer full or after 240 ms if less than 350 bytes received Modify To make the settings active press the Modify serial port button The new setting is im...

Страница 10: ...the address of the server to be contacted Auto Dial out The Auto dial out radio button enables automatic Telnet access from the LAN modem to the remote side automatic outgoing calls The connection is...

Страница 11: ...04 xmodus swiss GmbH 11 32 3 3 Web based statistics The statistics screen provides all the information regarding the packet frame oriented traffic on the Ethernet port These statistics can be helpful...

Страница 12: ...e Link or the User radio button The present state field shows the actual state of the port Port 2 This port is configurable as Collision LED or user defined output by either the Link or the User radio...

Страница 13: ...n is required to enter the terminal menu from a Telnet connection FTP Server This radio button defines if the FTP server of the module is accessible from the remote side The FTP server enables modific...

Страница 14: ...is interpreted as a request from the DTE to the modem to delete the previous character 4 1 3 Command line echo The modem may echo characters received from the DTE during command state and online comma...

Страница 15: ...Set data bits 7 8 set_par Set parity EVEN ODD NONE CONFIGURE SECURITY set_flow Set flow control XON HW None set_ftp Enable FTP Server set_high water Set flow stall 1 99 set_telnet Enable Telnet Server...

Страница 16: ...10 100 AUTO show_config Show network configuration show_config_o Show original network configuration save Save configuration to flash validate Validate temporary conf in Flash ping Ping test IP addres...

Страница 17: ...out set_auto_hw enable disable Dial out on DTR show_config Show serial configuration save Save configuration to flash help Display menu specific help quit Leave command mode 4 3 5 4 cr Display Input...

Страница 18: ...EB server authentication set_telnet_port Set telnet listener port number set_trusted_ip Trusted IP address for WEB TELNET show_config Show security configuration save Save configuration to flash help...

Страница 19: ...168 0 1 cr set_ip_mask set_ip_mask xxx xxx xxx xxx sets the IP subnet mask Example set_ip_mask 255 255 255 0 cr set_ip_gway set_ip_gway xxx xxx xxx xxx sets the Gateway address Example set_ip_gway 192...

Страница 20: ...tion This ensures that invalid settings do not render a device unreachable ping ping xxx xxx xxx xxx pings the IP Address entered Example ping 192 168 0 1 cr arp arp a show ARP table arp d delete ARP...

Страница 21: ...t from 1 99 in percent Example set_low_water 20 cr If buffer is reduced down to 20 data reception is restarted set_buf_size set_buf_size xxx sets input buffer packet size in bytes from 0 4K This comma...

Страница 22: ...sabled set_iac_tx set_iac_tx enable IAC Tx stuffing is enabled Telnet specific command set_iac_tx disable IAC Tx stuffing is disabled set_socket_tout set_socket_tout x If the Telnet session is inactiv...

Страница 23: ...efault set_dialin set_dialin enable Dial in to the LAN modem enabled incoming calls set_dialin disable Dial in disabled Note set_dialin_port must be defined prior to this command Example set_dialin_po...

Страница 24: ...ddress for automatic dial out function set_auto_hw enable cr Automatic dial out triggering with DTR line set_auto enable cr Enables the automatic dial out function Action upon activation of the DTR li...

Страница 25: ...ed as output get_ddr get_ddr 4 5 Read type of port 4 5 Example get_ddr 4 cr Answer Port direction INPUT read_port read_port 0 5 Read input status of ports 0 5 Example read_port 0 cr Answer Port state...

Страница 26: ...cr Answer of module New user data set set_id set_id xxxxxxxx Defines an identification name of the module Example set_id MODEM cr Defines MODEM as the identification name reject reject reset non saved...

Страница 27: ...ich will enable disable the Telnet Services in the LAN modem set_web set_web enable Enable WEB Server set_web disable Disable WEB Server Note This command enables the WEB HTTP Server of the module If...

Страница 28: ...d OK will be returned ATD ATD mode IP Port Manual telnet dial out command outgoing calls Mode T Telnet mode R RAW mode IP IP address Port port number optional Example ATD T 192 168 0 39 23 cr dial out...

Страница 29: ...he communications program used eg Hyperterminal or TeraTerm 3 The following menu will appear when the ENTER key is pressed Boot mode V1 0 Enter p to program new code Enter q to quit and re check Enter...

Страница 30: ...port number 8000 set_dialout_ip 192 168 1 77 cr Defines server IP address 192 168 1 77 set_dial_out enable cr Make sure that dial out is activated Then start the dial out procedure with ATD command A...

Страница 31: ...ust by triggering with either the DTR line CT108 2 or by data send to the modem The following commands configure this function set_auto set_auto enable Enables the automatic dial out function set_auto...

Страница 32: ...d the DCD line became active and data can be exchanged The serial interface must be defined to use RTS CTS flow control for this mode to operate correctly 6 5 Dial in In order for dial in to be suppor...