6- HTTPS SECURE COMMUNICATION & HTTP PORT (80) 

 
This card allows both 

http

 and 

https

 communication protocol. 

Factory set is http. To operate 

only

 under 

https

 protocol, user requires to disable http port 80. If not 

card will be able to communicate under any of these 2 protocols. 
 
To disable port 80 go to menu SYSTEM CONFIGURATION / WEB 
Make sure you have already logged in as administrator by introducing password: “12345678” 

 

FIG 6

 

  

 

 

 

SNMP06 LAN CARD 

REFERENCE MANUAL 

 

_______________________________________________________ 

SNMP-06  (161212)                                                                                                                  14 

 
HTTP PORT (80) 

 

1- Select System Configuration / Web menu, FIG 7. 
2- Select option LOGIN and password: 12345678. If you do not enter as administrator, modifications 
will be NOT saved. 
3-  Uncheck  option  Http  Port  and  APPLY  to  disable  port  80.  Only  if  port  80  is  disable,  card  will  be 
forced to communicate under HTTPS protocol. 

NOTE: If APPLY is not selected, changes will not be saved. A message OPERATION SUCCESSFUL must 
be shown. Select Accept button. 

 
FIG 7 

 

 
 
 
 
 

 

 

Содержание SNMP06

Страница 1: ...LED yellow ON connection detected OFF connection not detected NOTE 1 RESET Reset function reinitializes card with factory values It also eliminates user passwords To apply a reset follow next procedu...

Страница 2: ...d and revise user manual for Viewpower PRO software SNMP06 LAN CARD REFERENCE MANUAL _______________________________________________________ SNMP 06 161212 4 B COMMUNICATION FROM INTERNET NAVIGATOR Us...

Страница 3: ...AL _______________________________________________________ SNMP 06 161212 6 STATIC IP NETWORKS If the network where UPS will be connected is static IP network the network administrator must assign an...

Страница 4: ...ff and turned on alarm mute battery tests etc SYSTEM CONFIGURATION In this area important functions can be configured For example User name and password Emails sending SMS sending it requires external...

Страница 5: ...unt to be used to send emails Usually same tan email account name Need Authorization Check this option for accounts that require Authorization Need Auth Password Email account password APPLY It is nec...

Страница 6: ...server In the below example the value is 192 168 1 1 FIG 5 c Go back to WEB PRO card interface to mark option Use a static IP address Introduce DNS value and APPLY Wait for some seconds d Mark again...

Страница 7: ...sure you have already logged in as administrator by introducing password 12345678 FIG 6 SNMP06 LAN CARD REFERENCE MANUAL _______________________________________________________ SNMP 06 161212 14 HTTP...

Страница 8: ...igator must response with a message indicating communication is lost This is caused by port 80 is disable and HTTP communication is prohibited 5 At this moment you can check if HTTPS protocol is activ...

Отзывы: