The XT4964 must be mounted flush to a flat surface. Failing to mount the XT4964 to a flat
surface can lead to excessive strain on the top plate which can compromise the device
environmental seal and allow ingress of dust and water.
•
When screw mounted, it is recommended that the device is mounted with size #10-24
mechanical bolts and 5.5-6.0 lb.in torque be used. Failure to use the correct bolt size or to
apply the correct torque can result in damaging the mounting bracket. Do not attempt to
drill out the mounting hole to accept a larger bolt than specified as this will also damage
the bracket. When using a drill to screw mount the device, ensure the drill has clearance
from the top plate and does not come in contact with the top plate during installation.
Damage to the top plate from installation can compromise the device environmental seal
and allow ingress of dust and water. Please refer to the image below:
•
A small black button (Wake-up button) is located on top of one of the mounting holes.
When screw mounting the device it is important to be aware and stay clear of this button
as it can be damaged during the installation when not minded. Damaging this button or
permanently engaging the button will affect the device functionality.