Parameter
Name
Default
setting
Unit
Range
Modify
Effective
P2-49
Model loop gain
500
0.1Hz
10
~
20000
Anytime
At once
6.6 Adaptive
6.6.1 Overview
Adaptive function means that no matter what kind of machine and load fluctuation, it can obtain stable
response through automatic adjustment. It starts to automatically adjust when servo is ON.
6.6.2 Notes
When the servo unit is installed on the machine, it may produce instantaneous sound when
the servo is ON. This is the sound when the automatic notch filter is set, not the fault. For the
next time the servo is ON, no sound will be emitted.
When the inertia of the motor exceeds the allowable load, the motor may produce vibration.
At this time, please modify the adaptive parameters to match the present load inertia.
In adaptive operation, in order to ensure safety, the adaptive function should be executed at
any time when the servo enablement can be stopped or turned off urgently.
6.6.3 Operation steps
The factory settings are self-adaptive effective without modifying other parameters. The effectiveness
of self-adaptation is controlled by the following parameters.
Parameter
Meaning
Default setting
Modification
Effective
P2-01
n.□□□0
Adaptive shutdown
n.□□□1
Servo bb
Re-power on
n.□□□1
Adaptive Opening
6.6.4 Inertia mode and related parameters
The adaptive default parameter is defined as small inertia mode. If the load inertia far exceeds the
allowable load inertia of the motor (such as 60 times inertia of the 60 motor), the adaptive large inertia
mode can be turned on.
Parameter
Meaning
Default
setting
Modification
Effective
P2-03
n.0□□□
Adaptive small inertia mode
n.0□□□
Servo bb
Re-power
on
n.1□□□
Adaptive large inertia mode
Parameter
Meaning
Default setting
Modification
Effective
P2-05
Adaptive speed loop gain
400
Note1
Servo bb
At once
P2-10
Adaptive speed loop integral
500
Servo bb
At once
P2-11
Adaptive position loop gain
100
Servo bb
At once
P2-07
Adaptive inertia ratio
0
Servo bb
At once
P2-08
Adaptive speed observer gain
60
Servo bb
At once
P2-12
Adaptive stable max inertia ratio
30
Servo bb
At once
P2-16
Adaptive motor rotor inertia coefficient
100
Servo bb
At once
P2-19
Adaptive bandwidth
50
Note2
Servo bb
At once
Содержание DS5F Series
Страница 1: ...DS5F series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 02 20200217 2 3 ...
Страница 2: ......
Страница 41: ...39 3 2 5 Encoder feedback output signal Servo driver differential to collector upper device ...
Страница 124: ...122 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 202: ...200 Appendix 9 Torque speed characteristic curve ...
Страница 203: ...201 ...
Страница 204: ...202 ...