113
1. Speed feedback selection in full closed loop control
n.xxx□
Meaning
0
use motor encoder speed
1
use grating ruler speed
Full closed loop control is usually set to "use motor encoder speed (P9-01.0 = 0).". When
connecting only the direct driving servo motor and the high-resolution grating ruler, please set it to "use
grating ruler speed (P9-01.0 = 1)".
2. Z-phase signal source
n.xx□x
Meaning
0
motor encoder phase Z
1
grating ruler phase Z
P9-01.1 determines the z-phase source of the return to zero process.
3. Servo pulse output
n.x□xx
Meaning
0
Motor encoder phase ABZ output
1
Grating ruler ABZ output waiting for positioning completion
P9-01.2 determines the signal source of servo pulse output.
5.9.3.4 Frequency division setting of mechanical side grating ruler
parameter
Meaning
Default
setting
Unit
Range
Modify Effective
P9-05
Motor encoder feedback pulses
per turn /Low
0
PULSE
0
~
9999
Servo
bb
Re-power
on
P9-06
Motor encoder feedback pulses
per turn /High
0
PULSE
0
~
9999
Servo
bb
Re-power
on
P9-07
Grating ruler feedback pulses
per turn /Low
0
PULSE
0
~
9999
Servo
bb
Re-power
on
P9-08
Grating ruler feedback pulses
per turn /High
1
PULSE
0
~
9999
Servo
bb
Re-power
on
1. Mechanical side grating scale frequency division
=
Motor encoder feedback pulse per turn
External quadrature encoder pulse per turn
=
P9-06*10000+P9-05
P9-08*10000+P9-07
Motor encoder feedback pulse per turn = P9-06*10000+ P9-05. When the set value = 0, the resolution
of the encoder is set to the frequency division numerator.
Grating ruler feedback pulse per turn = P9-08*10000+ P9-07, P9-08*10000+ P9-07. When the setting
value = 0, set 10000 as the frequency division denominator.
Input the frequency division ratio of external grating ruler completely, cannot input it after reducible
division.
2. In the full closed-loop mode, it is recommended that P0-11 and P0-12 be set to 0, and the
electronic gear ratio of P0-13 and P0-14 is adopted. P0-11 and P0-12 can also be used on the premise
that the frequency division of external grating ruler is correct, otherwise, E-236 will be alarmed.
5.9.3.5 Alarm detection and clearing
parameter
Meaning
Default
setting
Unit
Range
Modify Effective
P9-02
Alarm value of excessive
deviation between motor and load
position
100
PULSE
0
~
65535
Servo
bb
At once
①
P9-02 deviation setting of encoder feedback (position) and full closed-loop grating scale
feedback (load position).
Содержание DS5F Series
Страница 1: ...DS5F series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 02 20200217 2 3 ...
Страница 2: ......
Страница 41: ...39 3 2 5 Encoder feedback output signal Servo driver differential to collector upper device ...
Страница 124: ...122 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 202: ...200 Appendix 9 Torque speed characteristic curve ...
Страница 203: ...201 ...
Страница 204: ...202 ...