Error4: the phone number only has read authority, but it wanted to write in
Error5: 4GBOX and PLC BWO read write failure
Error6: 4GBOX and PLC BWO read write failure
Error7: 4GBOX and PLC BWO read write failure
Error8: 4GBOX and PLC BWO read write failure
Note:
(1)
all the letters must be capitalized.
(2)
The command, register, operands are separated by a space, the whole message should not
exceed 99 English characters.
(3)
To send the character message, quotation mark must be English half angle “
(4)
Message function only support China mobile, China unicom.
3-5-2. Message (PLC => 4G-BOX => phone)
The 4GBOX will send message to user’s phone in certain condition. Please refer to below
example.
The trigger coil should be edge signal(falling or rising edge of pulse).
In the message configuration window, 4GBOX connects the left extension port of XD
series PLC, set the port to com3
First address can be D or HD, these registers cannot be used in other place of program
Support multi phone number type-in and set the phone number on the HMI, the using
method please refer to above picture, multi numbers are separated by “,”
The message support Chinse and English contents, such as “present temp {HD0}”, and
user will receive the message “present temp 30” for example. Register analysis function
supports single and double words, such as D, DD, HD, DHD, but not support DM.