1st. Overview 

 

XKC-C352 Intelligent non-contact liquid level controller and XKC-Y25-V liquid level sensor realize the function of 

liquid level high and low control: when the container liquid level is too low, the low liquid level alarm signal sent by the 

low liquid level sensor is triggered to trigger the C352 controller to close the relay to start the water pump Add the liquid 

level, when the liquid level reaches a certain height, the high liquid level sensor sends out a signal to trigger the C352 

controller to disconnect the relay and automatically stop the water pump to work in a cycle. Thereby, the function of 

automatic control of the container liquid level is realized, and the container liquid level is kept stable. 
 

2nd.Product Features 

1.AC180V~250V power supply   

2. Relay dry node output, suitable for various load control 

3. The control is diversified, and the pump can be controlled in manual or automatic mode 

4. The installation is simple and convenient, it can be installed with screws or electric box tracks 

 

3rd.Technical Parameters 

 

 

model 

XKC-C352 

Name 

C352 

 

Intelligent non-contact liquid level controller 

Input voltage 

AC180V-250V

50/60Hz 

Working current 

Working current ≤110 mA, static current consumption ≤20mA 

Load power 

Resistive load below 1.6KW (overload or three-phase load needs to be installed 

with AC contactor) 

Inductive load below 1KW (overload or three-phase load needs to be installed 

with AC contactor) 

Inductive loads refer to loads with inductive coils, such as motors, 

electromagnets, solenoid valves and so on. 

Alarm Output 

800W (resistive load) normally open / normally closed output 

output method 

Normally open/normally closed output 

input signal 

Low sensor signal input; 

High-position sensing signal input; 

Sensor interface voltage 

DC 12V 

Operating temperature 

-20~105℃ 

Dimensions 

115*90*40 

Содержание XKC-C352

Страница 1: ...250V table of Contents 1st Overview 2 2nd Product Features 2 3rd Technical Parameters 2 4th Correspondence diagram of signal input and relay output 3 5th Product selection model 3 6th Basic function...

Страница 2: ...id level is kept stable 2nd Product Features 1 AC180V 250V power supply 2 Relay dry node output suitable for various load control 3 The control is diversified and the pump can be controlled in manual...

Страница 3: ...osed end NC is open The low bit is 1 the high bit is 1 Normally open NO open normally closed NC closed Alarm status load output normally open open normally closed closed Relay disconnected state load...

Страница 4: ...oad output relay is disconnected to stop pumping and the alarm output relay is closed 5 Abnormal water overflow alarm the controller starts to pump water automatically and when the water surface rises...

Страница 5: ...enzhen XingKeChuang Technology Co Ltd Phone 86 0755 33523599 FAX 86 0755 33515410 URL http www sz xkc com Address 11th Floor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 5...

Страница 6: ...enzhen XingKeChuang Technology Co Ltd Phone 86 0755 33523599 FAX 86 0755 33515410 URL http www sz xkc com Address 11th Floor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 6...

Страница 7: ...xkc com Address 11th Floor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 7 15 1 XKC C352 1P wiring diagram The following figure uses the Intelligent non contact liquid leve...

Страница 8: ...xkc com Address 11th Floor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 8 15 2 XKC C352 2P wiring diagram The following figure uses the Intelligent non contact liquid leve...

Страница 9: ...o 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 9 15 3 XKC C352 3P wiring diagram The following figure uses the Intelligent non contact liquid level controller XKC C352 3 XKC...

Страница 10: ...loor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 10 15 4 XKC C352 3P wiring diagram The following figure uses the Intelligent non contact liquid level controller XKC C352...

Страница 11: ...48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 11 15 5 XKC C352 4P wiring diagram The following figure uses the Intelligent non contact liquid level controller XKC C352 4 XKC...

Страница 12: ...g Technology Co Ltd Phone 86 0755 33523599 FAX 86 0755 33515410 URL http www sz xkc com Address 11th Floor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 12 15 9th Product s...

Страница 13: ...he controller must be installed in a ventilated dry pest free and dust less environment The control board circuit of the controller is not waterproof please install it in a dry and ventilated place as...

Страница 14: ...ed to take effect or the purchase invoice receipt if you can t show it the product s free warranty period 12 months from the product shipment date and the latest DOA application deadline is 7 days fro...

Страница 15: ...Xinqiao Street Baoan District Shenzhen 15 15 caused by operations that do not follow this manual G Environmental protection This product meets the design requirements for environmental protection The...

Отзывы: