Server Requirements

The server hosting the X3522 must meet the following requirements:

• The server must have a 64-bit x86 processor.

• The server must be able to accept a half height half length 8-lane PCIe board.

• The server must meet the Thermal Specifications given in the Alveo X3522 Data Sheet

(

DS1002

).

NoteA desktop machine is unlikely to meet these specifications.

If the server does not meet these specifications the X3522 can overheat, causing preventive
measures such as reducing throughput or shutting down the card. See 

Chapter 6:

Troubleshooting

.

• The server should have an operating system installed that is supported by the X3522

software.

Refer to the Release Notes for the X3522 drivers and other software that you are using.

• The following optional packages are required:

kernel-headers

kernel-devel, or kernel-smp-devel (for Symmetric Multi-Processing systems).

Chapter 1: Introduction

UG1522 (v1.0) October 18, 2022

 

www.xilinx.com

Alveo X3522 Installation Guide

 6

Send Feedback

Содержание Alveo X3522

Страница 1: ...nguage from our products and related collateral We ve launched an internal initiative to remove language that could exclude people or reinforce historical biases including terms embedded in our softwa...

Страница 2: ...ation 18 Login 18 Installing the Network Software 18 Chapter 4 Card Bring Up and Validation 28 Running lspci 28 Running ethtool 28 Running ip 29 Running ping 30 Chapter 5 Next Steps 32 Chapter 6 Troub...

Страница 3: ...References 35 Revision History 36 Please Read Important Legal Notices 37 UG1522 v1 0 October 18 2022 www xilinx com Alveo X3522 Installation Guide 3 Send Feedback...

Страница 4: ...uration and test engineers responsible for testing and evaluating the X3522 Features The Xilinx Alveo X3522 is a single slot half length half height form factor passively cooled card that brings low l...

Страница 5: ...his variant is suitable for customers using the card purely as a vehicle to have a PCIe attached FPGA for a Vivado based workflow For example it can be used for trading acceleration or compute offload...

Страница 6: ...meet these specifications the X3522 can overheat causing preventive measures such as reducing throughput or shutting down the card See Chapter 6 Troubleshooting The server should have an operating sys...

Страница 7: ...hen handling hardware ATTENTION Il est fortement recommand d utiliser un bracelet ESD ou autres dispositifs antistatiques VORSICHT Beim Umgang mit Hardware m ssen sie immer ein Erdungs Armband oder ei...

Страница 8: ...Support place it back in its antistatic bag immediately Attention aux D charge lectrostatique ESD L ESD peut endommager les composants lectroniques lorsqu ils sont mal manipul s et peut entra ner des...

Страница 9: ...te sofort wieder in den antistatischen Beutel Before You Begin IMPORTANT Alveo cards are delicate and sensitive electronic devices equipment is to be installed by a qualified technician only This equi...

Страница 10: ...dem Server sollten sie sich zuerst elektrostatisch entladen indem Sie eine geerdete Metalloberfl che kurz ber hren oder ein passendes Antistatik Armband tragen Get Details of the Card 1 If necessary...

Страница 11: ...ket has also been supplied for PCIe slots that require this type of bracket To change the bracket that is fitted to the adapter 1 From the back of the adapter remove the screws securing the fitted bra...

Страница 12: ...ing 4 Connect the power cord and restart the computer Confirm the Card is Seen by the OS Now confirm the card is seen by the OS 1 Login as root 2 Confirm that you can see the PCIe devices for the X352...

Страница 13: ...ersion 3 Capabilities 60 MSI X Enable Count 64 Masked Capabilities 70 Express Endpoint MSI 00 Capabilities b0 Vital Product Data Capabilities 100 Advanced Error Reporting Capabilities 1c0 19 Capabilit...

Страница 14: ...15 Capabilities e80 Vendor Specific Information ID 0020 Rev 0 Len 010 Connect the Card to the Network If you are installing an X3522 low latency network adapter you can now connect it to the network...

Страница 15: ...eur fibre optique ou les c bles car les faisceaux laser peuvent endommager votre vue WARNUNG Schauen Sie nicht direkt in den Faser Transceiver oder die Kabel da die Laserstrahlen Ihr Sehverm gen sch d...

Страница 16: ...rstrahlen Ihr Sehverm gen sch digen k nnen To remove a fiber optic cable 1 Remove the cable from the adapter bracket and replace the fiber optic connector cover 2 Pull the plastic or wire tab to relea...

Страница 17: ...nce of any physical link Blinking red if a command such as ethtool identify has been issued to identify the network port The activity LED for a cage is Blinking green when there is link activity on al...

Страница 18: ...the X3522 host as root Installing the Network Software This section tells you how to install the drivers required by an X3522 low latency network adapter Two drivers are required Auxiliary bus driver...

Страница 19: ...u r seau pilote L utilisateur doit disposer des autorisations root pour installer le reseau pilote WICHTIG Installieren Sie den X3522 Karte im Host Rechner bevor Sie mit der Installation des Netzwerkt...

Страница 20: ...urce RPM 1 Start a web browser 2 Open the product website see Product Website 3 Download the following package XN 201056 LS Auxiliary Bus Driver Source RPM package Build the Auxiliary Bus Driver Binar...

Страница 21: ...Product Website 3 Download the following package XN 201053 LS Alveo X3522 Net Driver Source RPM package Build the Network Driver Binary RPM To build the network driver binary RPM for the currently ru...

Страница 22: ...omit this section IMPORTANT Si vous avez choisi d installer les pilotes partir des packages RPM omettez cette section WICHTIG Wenn Sie die Treiber aus RPM Paketen installiert haben berspringen Sie di...

Страница 23: ...Auxiliary Bus Driver Now install the auxiliary bus driver DKMS package For example on an Ubuntu Debian server 1 Locate the Auxiliary Bus Driver Source Debian package that you downloaded See Download t...

Страница 24: ...2 interface 1 List all interfaces in the server ip link 2 Search the output for the X3522 interface It can be recognized by the MAC address that you read from the QR code see Get Details of the Card F...

Страница 25: ...ce connect la carte X3522 votre r seau vous devrez mettre les param tres adapt s votre r seau Si n cessaire demandez les votre administrateur syst me WICHTIG Wenn Sie stattdessen den X3522 mit Ihrem N...

Страница 26: ...onfiguration to use the following static values for the X3522 nmcli connection modify NAME ipv4 addresses 192 168 10 10 24 nmcli connection modify NAME ipv4 method manual or the following static value...

Страница 27: ...ection show enp1s0f2 ipv4 method manual The ipv4 method should be manual as above 2 Confirm that the values are correct nmcli fields IP4 connection show NAME For example nmcli fields IP4 connection sh...

Страница 28: ...link is up and the correct network driver is in use ping The ping Linux command is used to confirm that network traffic is passing Running lspci 1 Run the following command sudo lspci v d 10ee 2 Refer...

Страница 29: ...driver xilinx_efct version version number 4 Confirm that the xilinx_efct network driver is shown its version is as expected Note The actual version number might differ from the previous example Runni...

Страница 30: ...q_codel master virbr0 state DOWN group default qlen 1000 link ether 52 54 00 2f 47 fc brd ff ff ff ff ff ff 14 enp1s0f0np0 BROADCAST MULTICAST UP LOWER_UP mtu 1500 qdisc fq_codel state UP group defaul...

Страница 31: ...l 64 time 0 068 ms 64 bytes from 192 168 10 10 icmp_seq 2 ttl 64 time 0 074 ms 64 bytes from 192 168 10 10 icmp_seq 3 ttl 64 time 0 080 ms 64 bytes from 192 168 10 10 icmp_seq 4 ttl 64 time 0 050 ms 6...

Страница 32: ...variant can be upgraded to hybrid mode The upgrade adds support for applications that can be inserted into the datapath to process network traffic and act upon it For more information see the Alveo X...

Страница 33: ...n the power supplies The system microcontroller subsequently records that in its logs Allow card to cool Increase fan speed Ensure that operating ambient conditions do not exceed the Thermal Specifica...

Страница 34: ...ee Determine Interface Names For example ethtool enp1s0f2 Examine the network driver information for the interface ethtool i interface where interface is the first interface on the card For example et...

Страница 35: ...linx Design Tools DocNav At the Linux command prompt enter docnav Xilinx Design Hubs provide links to documentation organized by design tasks and other topics which you can use to learn key concepts a...

Страница 36: ...gn Suite User Guide Designing with IP UG896 6 Vivado Design Suite User Guide Programming and Debugging UG908 Additional Xilinx Resources 1 Xilinx licensing website https www xilinx com getproduct 2 Vi...

Страница 37: ...splay the Materials without prior written consent Certain products are subject to the terms and conditions of Xilinx s limited warranty please refer to Xilinx s Terms of Sale which can be viewed at ht...

Страница 38: ...ds included herein are trademarks of Xilinx in the United States and other countries PCI PCIe and PCI Express are trademarks of PCI SIG and used under license All other trademarks are the property of...

Отзывы: