4.4.3.9.11 Set device debug level
Send query command: FE 01 21 2B 0A 01
SOF
Length
Command
Data
FCS
FE
01
21 2B
command
(1 byte)
01
0A
Respone to query command: FE 03 61 2B 0A 00 00 43
SOF
Length
Command
Data
FCS
FE
03
61 2B
command
(1 byte)
Respone value
(2 bytes)
43
0A
00 00
Data Description: ( little-endian)
Respone value:
00 00 = Close all debug messages
01 00 = Info the important debug messages
02 00 = Info all debug messages
Send set command: FE 03 21 2B 0A 00 00 03
SOF
Length
Command
Data
FCS
FE
03
21 2B
command
(1 byte)
parameter value
(2 bytes)
03
0A
00 00
Data Description: ( little-endian)
Parameter value:
00 00 = Close all debug messages
01 00 = Info the important debug messages
02 00 = Info all debug messages
Default :00 00
Respone to set command: FE 01 61 2B 00 4B / FE 01 61 2B 02 49
SOF
Length
Command
Data
FCS
FE
01
61 2B
Command state
(1 byte)
4B
00
Data Description: 00 = Success
02 = Failure