![xFusion Digital Technologies FusionServer G5500 V7 Скачать руководство пользователя страница 95](http://html2.mh-extra.com/html/xfusion-digital-technologies/fusionserver-g5500-v7/fusionserver-g5500-v7_technology-white-paper_5005726095.webp)
NO TE
● When a single fan is faulty, the highest operating temperature is 5ºC (9ºF) lower than the
rated value.
● When a single fan is faulty, the system performance may be affected.
● It is recommended that servers be deployed at an interval of 1U to reduce server noise and
improve server energy efficiency.
A.4 Nameplate
Certified Model
Remarks
G5500 V7
Global
H52GP-07
Global
Note: The nameplate depends on the actual product.
A.5 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can configure these features for better performance.
For details about RAS features, see the
FusionServer Sapphire Rapids Platform
Server RAS Feature Technical White Paper
.
A.6 Sensor List
Sensor
Description
Component
Inlet Temp
Air inlet temperature
Right mounting ear plate
Outlet Temp
Air outlet temperature
BMC card
PCH Temp
PCH bridge temperature
Mainboard
PCH Status
PCH chip fault diagnosis
health status
Mainboard
1711 Core Temp
Core temperature of the
1711 chip
BMC card
SSD Max Temp
Maximum SSD
temperature (reported by
BMA)
SSD
CPU
N
Core Temp
CPU core temperature
CPU
N
N
indicates the CPU
number. The value is
1
or
2
.
FusionServer G5500 V7 Server
Technical White Paper
A Appendix
Issue 02 (2023-12-13)
Copyright © xFusion Digital Technologies Co., Ltd.
88