background image

FusionServer 2488H V7 Server

Technical White Paper

Issue

01

Date

2023-09-01

xFusion Digital Technologies Co., Ltd.

Содержание FusionServer 2488H V7

Страница 1: ...FusionServer 2488H V7 Server Technical White Paper Issue 01 Date 2023 09 01 xFusion Digital Technologies Co Ltd...

Страница 2: ...se of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this docu...

Страница 3: ...Indicates a hazard with a medium risk which if not avoided could result in death or serious injury Indicates a low level hazard which if not avoided could result in minor or moderate injury Indicates...

Страница 4: ...sue Date Description 01 2023 09 01 This issue is the first official release FusionServer 2488H V7 Server Technical White Paper About This Document Issue 01 2023 09 01 Copyright xFusion Digital Technol...

Страница 5: ...Architecture 22 5 4 1 3 Memory Compatibility 24 5 4 1 4 Memory Module Installation Rules 25 5 4 1 5 Positions of the Memory Modules 26 5 4 1 6 Memory Protection Technologies 29 5 5 Storage 29 5 5 1 D...

Страница 6: ...and Hardware Compatibility 62 8 Safety Instructions 63 8 1 Security 63 8 2 Maintenance and Warranty 66 9 System Management 68 10 Certifications 70 A Appendix 71 A 1 Chassis Label Information 71 A 1 1...

Страница 7: ...5 U Z 89 C Acronyms and Abbreviations 90 C 1 A E 90 C 2 F J 91 C 3 K O 92 C 4 P T 93 C 5 U Z 95 FusionServer 2488H V7 Server Technical White Paper Contents Issue 01 2023 09 01 Copyright xFusion Digita...

Страница 8: ...emory computing The 2488H V7 features high performance computing large capacity storage low power consumption high scalability high reliability and easy management and deployment and high virtualizati...

Страница 9: ...and I O performance The server supports a maximum of 9 standard PCIe slots Among these slots a maximum of six can be PCIe x16 slots two of which support PCIe 5 0 Supports one GE 10GE 25GE 100GE OCP 3...

Страница 10: ...tions It can be bound to any network port of the server s OCP 3 0 NIC or other standard PCIe NICs that support the NC SI function It allows users to enable or disable the virtual local area network ID...

Страница 11: ...cy scaling optimize heat dissipation and reduce overall system power consumption The improved thermal design with energy efficient fans ensures optimal heat dissipation and reduces system power consum...

Страница 12: ...module 2 4 Chassis 5 PSU 6 Power shelf 7 PSU backplane 8 Mezzanine RAID controller card or M 2 SSD 9 Air duct 10 Supercapacitor 11 Intrusion sensor 12 Fan board FusionServer 2488H V7 Server Technical...

Страница 13: ...ear plate 19 Heat sinks 20 Remote heat sinks 21 Processors 22 Cable management arms CMAs 23 Mainboard 24 Memory modules 25 OCP 3 0 NIC 26 PCIe expansion board 27 BMC card FusionServer 2488H V7 Server...

Страница 14: ...Scalable processors Sapphire Rapids It supports 64 DDR5 DIMMs The processors interconnect with each other through three UltraPath Interconnect UPI links at a speed of up to 16 GT s FusionServer 2488H...

Страница 15: ...GA USB 3 0 and serial port RJ45 The BMC management chip integrated on the mainboard supports ports such as a video graphic array VGA port a management network port and a serial port FusionServer 2488H...

Страница 16: ...O Expansion 5 8 PSUs 5 9 Fan Modules 5 10 LCD 5 11 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 drive pass through configuration 8 x SAS SATA Figure 5 1 Front view FusionServer 2488H V7 Server Tech...

Страница 17: ...out label plate with an SN label 25 x 2 5 drive EXP configuration 25 x SAS SATA Figure 5 3 Front view 1 SAS SATA drive 2 Slide out label plate with an SN label 5 1 2 Indicators and Buttons Indicator...

Страница 18: ...A 8 x NVMe Figure 5 5 Indicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexIO card presence indicator 6 iBMC...

Страница 19: ...dy green The device is powered on Blinking yellow The iBMC is starting The power button is locked and cannot be pressed The iBMC is started in about 1 minute and then the power indicator is steady yel...

Страница 20: ...tem Steady green The device is operating properly FlexIO card presence indicator Off The FlexIO card is not detected Blinking green at 0 5 Hz The FlexIO card is detected but is not powered on Blinking...

Страница 21: ...rts on the front panel 1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port 25 x 2 5 drive EXP configuration 25 x SAS SATA Figure 5 9 Ports on the front panel 1 USB 3 0 port 2 iBMC direct c...

Страница 22: ...s box of the browser on the local PC USB port USB 3 0 2 Used to connect to a USB 3 0 device NOTICE Before connecting an external USB device ensure that the USB device functions properly otherwise it m...

Страница 23: ...ser modules on the rear panel Figure 5 11 Indicators on the rear panel 1 Health status indicator 2 Data transmission status indicator of the management network port 3 Connection status indicator of th...

Страница 24: ...z The input is normal and the server is in the standby state The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online S...

Страница 25: ...ing red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly 5 2 3 Ports Port Pos...

Страница 26: ...M USB 3 0 port USB 3 0 2 Used to connect to a USB 3 0 device NOTE Before connecting an external USB device ensure that the USB device functions properly otherwise it may adversely impact the server Th...

Страница 27: ...lt the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Figure 5 13 Positions of the processors 5 4 Memory 5 4 1 DDR5 Memory 5 4 1 1 Memory Identifier You can...

Страница 28: ...e of the memory interface PC5 DDR5 5 Maximum memory speed 4800 MT s 6 Memory latency parameters CL nRCD nRP A 34 34 34 B 40 40 40 C 42 42 42 7 DIMM type RD0 reference design for version RDIMM D0 8 SPD...

Страница 29: ...nnel is not populated the memory modules in secondary memory channels cannot be used Table 5 5 Memory channels CPU Channel Memory Slot CPU 1 A primary DIMM000 A A DIMM001 I B primary DIMM010 B B DIMM0...

Страница 30: ...O H primary DIMM170 H H DIMM171 P CPU3 A primary DIMM200 A A DIMM201 I B primary DIMM210 B B DIMM211 J C primary DIMM220 C C DIMM221 K D primary DIMM230 D D DIMM231 L E primary DIMM240 E E DIMM241 M F...

Страница 31: ...the following two speed values Memory speed supported by a CPU Maximum operating speed of a memory module The DDR5 memory modules of different types RDIMM and RDIMM 3DS and specifications capacity bi...

Страница 32: ...DIMM GB 16 32 64 128 256 Type RDIMM RDIMM RDIMM RDIMM 3 DS RDIMM 3 DS Rated speed MT s 4800 4800 4800 4800 4800 Operating voltage V 1 1 1 1 1 1 1 1 1 1 Maximum number of DDR5 DIMMs in a servera 64 64...

Страница 33: ...rts up to 64 DDR5 memory modules To maximize memory performance it is advised to use balanced memory configuration Observe the memory module installation rules when configuring memory modules For deta...

Страница 34: ...e 5 16 Recommended slots for DDR5 memory modules 2 processors FusionServer 2488H V7 Server Technical White Paper 5 Hardware Description Issue 01 2023 09 01 Copyright xFusion Digital Technologies Co Lt...

Страница 35: ...e 5 17 Recommended slots for DDR5 memory modules 4 processors FusionServer 2488H V7 Server Technical White Paper 5 Hardware Description Issue 01 2023 09 01 Copyright xFusion Digital Technologies Co Lt...

Страница 36: ...DC SR Adaptive Double Device Data Correction Multiple Region ADDDC MR Partial Cache Line Sparing PCLS HBM only 5 5 Storage 5 5 1 Drive Configurations and Drive Numbering 5 5 1 1 8 x 2 5 Drive Pass Thr...

Страница 37: ...CE The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card This section uses the drive numbers identified by a RAID controller card that adop...

Страница 38: ...Figure 5 19 Drive numbering Table 5 9 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7...

Страница 39: ...12 x 2 5 drive pass through configuration 1 Front drive 12 x 2 5 Slots 0 to 3 support only SATA drives Slots 4 to 7 support SATA NVMe drives Slots 8 to 11 support only NVMe drives SATA drive PCH pass...

Страница 40: ...nsult the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive numbering NOTICE The drive numbers identified by the RAID controller card vary depending on th...

Страница 41: ...of the 12 x 2 5 drive pass through configuration 2 in Table 5 10 Figure 5 21 Drive numbering Table 5 12 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by th...

Страница 42: ...gurations Configuratio n Front Drive Rear Drive Built in Drive Drive Management Mode 25 x 2 5 drive EXP configuration 1 Front drive 25 x 2 5 Slots 0 to 24 support only SAS SATA drives SAS SATA drive 1...

Страница 43: ...Server Maintenance and Service Guide Drive numbering of the 25 x 2 5 drive EXP configuration in Table 5 13 Figure 5 22 Drive numbering Table 5 14 Drive numbering Drive No Drive Number Displayed on the...

Страница 44: ...2 Drive Indicators SAS SATA Drive Indicators Figure 5 23 SAS SATA drive indicators Table 5 15 SAS SATA drive indicator description Activity Indicator Green Fault Indicator Red Blue Description Off Off...

Страница 45: ...NVMe drive indicator If the VMD function is enabled and the latest VMD driver is installed the NVMe drives support surprise hot swap Table 5 16 NVMe drive indicator description VMD function enabled A...

Страница 46: ...e at 4 Hz The NVMe drive is being located Off Blinking red at 0 5 Hz The NVMe drive has completed the hot swap process and is removable Off Blinking red at 2 Hz The NVMe drive is being hot swapped Ste...

Страница 47: ...ve or see OS and Parts Compatibility in the Compatibility Checker When IB cards are used to build an IB network ensure that the IPoIB modes of the IB cards at both ends of the network connection are t...

Страница 48: ...tio n CPU PCIe Port Number PCIe Device Supported by the PCIe Slot or Port I O module 1 Slot 1 PCIe4 0 x16a x16 b CPU 4 Port2A Full height half length FHHL Slot 2 PCIe 5 0 x16 x16 CPU 1 Port2A FHHL Slo...

Страница 49: ...not be less than that of the inserted PCIe card The full height full length FHFL PCIe slots are compatible with FHFL PCIe cards full height half length FHHL PCIe cards and half height half length HHHL...

Страница 50: ...SUs are configured If the input voltage ranges from 100 V AC to 127 V AC the output power decreases to 1300 W If the input voltage ranges from 200 V AC to 220 V AC the output power decreases to 2500 W...

Страница 51: ...r components and enables users to set the IP address of the iBMC management network port on the server The LCD and the server iBMC form an LCD subsystem The LCD directly obtains device information fro...

Страница 52: ...ion Status Displays the port 80 status serial number component status and component alarms of the server Monitor Displays the current power CPU temperature and inlet temperature of the server FusionSe...

Страница 53: ...formation and firmware version Setting Sets the IP address of the iBMC management network port For details about how to use the LCD see the FusionServer Rack Server LCD User Guide 5 11 Boards FusionSe...

Страница 54: ...5 11 1 Mainboard Figure 5 31 Mainboard FusionServer 2488H V7 Server Technical White Paper 5 Hardware Description Issue 01 2023 09 01 Copyright xFusion Digital Technologies Co Ltd 47...

Страница 55: ...connector PDB MIS CONN J2014 16 PCIe riser 2 slot PCIE RISER2 CPU2 J13001 17 VROC KEY J6066 18 Built in USB 3 0 port INNER USB3 0 J6067 19 NC SI connector NCSI CONN J31 20 External USB 3 0 port USB 3...

Страница 56: ...name BC15HBBA All drive configurations in 5 5 1 1 8 x 2 5 Drive Pass Through Configuration support this backplane Figure 5 32 8 x 2 5 drive pass through backplane No Connector Managed Drive Slot 1 Ba...

Страница 57: ...ot9 3 UBC connector 2 UBC2 J2 Slot6 Slot7 4 UBC connector 1 UBC1 J1 Slot4 Slot5 5 Backplane signal connector HDD BP J19 6 Power connector HDD_POWER J21 7 mini SAS HD connector PORT A J28 Slot 0 to 3 8...

Страница 58: ...gnal connector for I O module 2 REAR_BP1 J2301 4 Backplane signal connector HDD BP J302 5 Power connector HDD POWER J301 6 mini SAS HD connector PORT B J2203 7 mini SAS HD connector PORT A J2202 Fusio...

Страница 59: ...tor J1 4 Drive backplane connector BP J15 5 11 4 Fan Board Figure 5 36 Fan board 1 Fan board signal connector MISC CONN J3 2 Fan board power connector POWER CONN1 J2 3 Fan connector FAN1 J5 4 Fan conn...

Страница 60: ...N6 J10 5 11 5 Built in M 2 Adapter Board Figure 5 37 Built in M 2 adapter board 1 Signal connector M 2CONN J1 2 High speed connector Simline X8 J2 FusionServer 2488H V7 Server Technical White Paper 5...

Страница 61: ...controller and eight memory channels per processor Built in PCIe controller supporting PCIe 5 0 and 80 lanes per processor Three UPI buses between processors providing up to 16 GT s transmission per c...

Страница 62: ...d specifications capacity bit width rank and height cannot be used together A server must use DDR5 DIMMs of the same P N code NOTE The preceding information is for reference only For details see Searc...

Страница 63: ...use enterprise level SSDs or HDDs with high DWPD The M 2 SSD is not recommended for write intensive service software due to poor endurance Do not use M 2 SSDs for cache Supports hot swap of SAS SATA N...

Страница 64: ...patibility Checker I O expansion Supports ten PCIe slots Supports one PCIe slot dedicated for an OCP 3 0 NIC and nine standard PCIe slots For details see 5 7 1 PCIe Cards and 5 7 3 PCIe Slot Descripti...

Страница 65: ...by the operating system is provided If both the front and rear VGA ports are connected to monitors only the monitor connected to the front VGA port displays information System management UEFI iBMC NC...

Страница 66: ...Storage humidity within one year 20 to 75 Maximum change humidity rate 20 per hour Air volume 96 CFM Operating altitude 3050 m 10 006 56 ft When the server configuration complies with ASHRAE Classes A...

Страница 67: ...6 62 Bels LpAm 49 1 dBA NOTE Actual sound levels generated during operation vary depending on the configuration load and ambient temperature NOTE SSDs and HDDs including NL SAS SAS and SATA cannot be...

Страница 68: ...m to 940 mm 24 02 in to 37 01 in between the front and rear mounting bars NOTE For a 1100 mm 43 31 in deep cabinet a distance of 70 mm to 110 mm 2 76 in to 4 33 in between the front mounting bar and t...

Страница 69: ...tency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact technical support to apply for proof of concept...

Страница 70: ...f this device may cause radio interference Human Safety This device is not suitable for use in places where children may be present Only certified or authorized personnel are allowed to install equipm...

Страница 71: ...removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and e...

Страница 72: ...ers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device hold the bottom o...

Страница 73: ...riptions in the documentation are for reference only Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per...

Страница 74: ...For details on warranty see Warranty FusionServer 2488H V7 Server Technical White Paper 8 Safety Instructions Issue 01 2023 09 01 Copyright xFusion Digital Technologies Co Ltd 67...

Страница 75: ...s stable uninterrupted 24 7 system operation by providing the following features The last screenshot and video recording function when the system crashes makes it impossible to analyze the cause of th...

Страница 76: ...configuration and upgrades to simplify server installation and configuration Diversified network protocols Supports NTP to improve the device time configuration capability and synchronizes the network...

Страница 77: ...Region Certification Standard China CCC GB4943 1 2011 GB T 9254 1 2021 GB17625 1 2012 FusionServer 2488H V7 Server Technical White Paper 10 Certifications Issue 01 2023 09 01 Copyright xFusion Digita...

Страница 78: ...cess tag 4 Product SN NOTE For details see Product SN 5 Reserved space for customized label 6 Pressure proof label NOTE This label warns users not to place any objects on top of a rack mounted device...

Страница 79: ...tails see A 4 Nameplate 2 Device name 3 Power supply requirements 4 Enterprise Standard Number 5 Vendor information 6 Certification marks A 1 1 2 Certificate Figure A 3 Certificate example FusionServe...

Страница 80: ...finished server N a spare part 4 0 a value for the reserved digit 5 Year two characters 6 Month one character Digits 1 to 9 indicate January to September respectively Letters A to C indicate October t...

Страница 81: ...A 5 Quick access label example Table A 4 Quick access label description No Description 1 IP address of the iBMC management network port 2 Subnet mask of the iBMC management network port 3 Default iBM...

Страница 82: ...and QR codes of technical resources The pictures are for reference only For details see the actual product The quick start guide is optional For details see the actual product A 1 3 Chassis Tail Label...

Страница 83: ...e years 2001 to 2009 respectively Letters A to H indicate years 2010 to 2017 respectively Letters J to N indicate years 2018 to 2022 respectively Letters P to Y indicate years 2023 to 2032 respectivel...

Страница 84: ...ectively Letters P to Y indicate years 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits...

Страница 85: ...2 GPU cards are supported and OCP 3 0 NICs with 100GE ports or ports of higher rate are not supported when the CPU TDP equals to or is greater than 270 Wb GPU cards each of which has a capacity of or...

Страница 86: ...s with 100 GE ports or ports of higher rate are not supported when the CPU TDP equals to or is greater than 270 Wb GPU cards each of which has a capacity of or more than 128 GB are not supported CPUs...

Страница 87: ...equals to or is higher CPUs with TDP that equals to or is lower than 270 W are supporteda Two 200GE IB cards are supported when the CPU TDP equals to or is lower than 185 Wc OCP 3 0 NICs with 100GE p...

Страница 88: ...ot 2 slot 8 slot 3 slot 9 It is recommended that servers be deployed at an interval of 1U to reduce server noise and improve server energy efficiency A 4 Nameplate Certified Model Remarks H24H 07 Glob...

Страница 89: ...y RTC battery status An alarm is generated when the voltage is lower than 1 V RTC battery on the mainboard Power Button Power button pressed status Mainboard and power button CPUN 12V 12 V voltage sup...

Страница 90: ...er The value ranges from 1 to 4 CPUN Status CPU status detection CPUN N indicates CPU number The value ranges from 1 to 4 FAN Power Total power consumption of fan modules in the power on state Fan mod...

Страница 91: ...atus PSU N N indicates PSU number The value ranges from 1 to 2 PSN Fan Status PSU fan fault status PSU N N indicates PSU number The value ranges from 1 to 2 PSN Temp PSU temperature PSU N N indicates...

Страница 92: ...ive on the riser card M 2 drive N N indicates M 2 drive number RAID Status RAID controller card health status RAID controller card RAID PCIE ERR RAID controller card fault diagnosis health status RAID...

Страница 93: ...card N N indicates PCIe slot number IBN Temp IB NIC temperature sensor IB card N N indicates PCIe slot number OCP1 Temp OCP card chip temperature sensor OCP 3 0 NIC CPU Usage CPU usage N A Memory Usa...

Страница 94: ...ement of the devices E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox...

Страница 95: ...he server It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses th...

Страница 96: ...special computer that provides services for clients over a network system event log SEL Event records stored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit de...

Страница 97: ...B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CCC China Compulsory Certification CD calendar day CE Conformite Europeenne CIM Common Information Model...

Страница 98: ...rer Association EDB Execute Disable Bit EID enclosure ID EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber...

Страница 99: ...otocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations p...

Страница 100: ...k Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK Power...

Страница 101: ...single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Ma...

Страница 102: ...ed Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by...

Страница 103: ...WSMAN Web Service Management FusionServer 2488H V7 Server Technical White Paper C Acronyms and Abbreviations Issue 01 2023 09 01 Copyright xFusion Digital Technologies Co Ltd 96...

Отзывы: