TROUBLESHOOTING
1. Power indicator LED in top plate is not lit
• Main fuse or fuse in amplifier blown?
• Remote wire properly connected?
Is there remote voltage (12 V)?
• Amplifier overheated?
2. Power indicator LED in top plate lights RED
• Protection active. Check the speakers and
speaker wires for short-circuit!
• Battery voltage low (<10,2 V)?
• DC on one of the speaker outputs?
• Overload.
3. Distortions at medium level
• Please check the speaker connections
for short-circuits.
• Are the speakers OK?
• Radio volume turned up too high.
Better turn up the amplifier’s level controls.
4. Alternator whine and similar noise
• Bad ground connections?
• Use ONE ground contact only!
• RCA cables run too close to power cables?
In case of further trouble, please ask your local
XETEC