QLS-8100 Xe
3-9
6
Press the + or - key until Gap is displayed.
7
Press the SELECT key. The display will show the following prompt:
8
Press
and
hold
the FORM FEED/ADVANCE key until the liner is inside
the sensor bracket. On notched media, temporarily slide the media out so
that it is completely clear of the sensor assembly.
9
Press the SELECT key. The display will show the following prompt:
10
Press
and
hold
the FORM FEED/ADVANCE key until the next label is
inside the Gap sensor.
11
Press the SELECT key. The display will show the following prompt:
12
Press and hold the FORM FEED/ADVANCE key until the next gap is
positioned behind the Media Sensor Assembly and in close proximity to
the guide arrow indicated on the center plate.
13
Press the SELECT key and observe the gap size on the display. The gap
size should be the same as the measured gap of your media and the
following message will be displayed:
Gap
Calibration OK
Place Gap @ Arrow
Then Press Select
Place Media @ Sensor
Then Press Select
Place Liner @ Sensor
Then Press Select
Calibrate
Gap
Содержание QLS-8100XE
Страница 2: ......
Страница 14: ...1 4 Quick start ...
Страница 19: ...QLS 8100 Xe 2 5 Side view ...
Страница 46: ...3 14 Loading media and calibration ...
Страница 149: ...QLS 8100 Xe A 1 Appendix A Physical Data ...
Страница 153: ...QLS 8100 Xe B 1 Appendix B Specifications ...
Страница 156: ...B 4 Specifications ...
Страница 157: ...QLS 8100 Xe C 1 Appendix C Replacement Parts ...
Страница 160: ...C 4 Replacement parts ...
Страница 161: ...QLS 8100 Xe D 1 Appendix D Color QuickLabel 99 Pro setup ...
Страница 166: ...D 6 Color QuickLabel 99 Pro setup ...
Страница 167: ...QLS 8100 Xe E 1 Appendix E Windows Printer Driver Setup ...
Страница 175: ...QLS 8100 Xe F 1 Appendix F Format error codes ...
Страница 180: ...F 6 Format error codes ...
Страница 181: ...QLS 8100 Xe G 1 Appendix G Menu Structure ...
Страница 182: ...G 2 Menu Structure ...