6-6
Alignment & Adjustments
Service Manual
6.1.2.5 Sensor Test
- These Functions are considered to check the present state (normal or not) of the Sensors.
1. Press the "Menu Key", until finding "Sensors Test" message on the panel.
2. Press the "Select Key", when it's found.
3. Press the "Arrow keys" (< / >), until finding a suitable function.
4. Press the "Select Key", when it's found.
3. Touch a sensor you would like to test.
4. Confirm a message on the LCD window for the state of it.
Sub Menu
Description
Display(LCD)
Before touching
After touching
Tray1 Sensor
After the tray 1 is gotten down, touch the sensor
Tray 1 Sensor Off
Tray 1 Sensor On
and confirm the message changed "Tray 1 Sensor Off"
to "Tray 1 Sensor On"
Tray2 Sensor
After the tray 2 is pulled out, touch the sensor
Tray 2 Sensor Off
Tray 2 Sensor On
and confirm the message changed "Tray 2 Sensor Off"
to "Tray 2 Sensor On".
Tray3 Sensor
After the tray 3 is pulled out, touch the sensor
Tray 3 Sensor Off
Tray 3 Sensor On
and confirm the message changed "Tray 3 Sensor Off"
to "Tray 3 Sensor On".
Duplex Sensor
After the back cover is open, push a paper into the
Duplex Sensor Off
Duplex Sensor On
duplex path and confirm the message changed
"Duplex Sensor Off" to "Duplex Sensor On".
Cover Open
After the cover is open, touch the sensor and confirm
Cover Open
Cover Close
Sensor
the message changed "Cover Open" to " Cover Close"
Feed Sensor
Touch the Feed sensor.
Feed Off
Feed On
Exit Sensor
Touch the Feed sensor.
Exit Off
Exit On
Содержание Phaser 3450
Страница 12: ...3 4 Specifications Service Manual ...
Страница 28: ...4 16 Summary of Product Service Manual ...
Страница 75: ...6 20 Alignment Adjustments Service Manual ...
Страница 103: ...7 28 TROUBLESHOOTING Service Manual ...
Страница 129: ...9 2 BLOCKDIAGRAM Service Manual ...
Страница 131: ...10 2 CONNECTION DIAGRAM Service Manual ...