Xerox 4590 EPS/4110 EPS System Administration Guide
4-49
4. Setups
NOTE: The maximum value that can be set for the HP-GL/2 Auto
Layout Memory option varies according to the available memory
capacity.
Receiving Buffer - LPD
Spool
•
Off:
When Off is selected, the machine will not use spooling.
During the LPD print process for one client, data cannot be
received over that same interface from a different client. Set a
value for the dedicated LPD receiving buffer memory capacity
from 1024-2048 KB, in 32 KB increments.
•
Memory Spool:
When selected, the machine will use
spooling. The receiving buffer for spooling uses memory.
When this candidate value is selected, set the memory
capacity of the receiving buffer for spooling, from 0.50 MB to
32.00 MB, in 0.25 MB increments.
NOTE: Notice that print data exceeding the set memory
capacity is not accepted. In such cases, select Hard Disk or
Off.
•
Hard Disk Spool:
When selected, the machine will use
spooling. The receiving buffer for spooling uses the hard disk.
Receiving Buffer - NetWare
Set the NetWare receiving buffer. Set a value from 64 to 1024 KB,
in 32 KB increments.
Receiving Buffer - SMB
Spool
•
Off:
When Off is selected, the machine will not use spooling.
While SMB print processing is being carried out for one client,
data cannot be received over the same interface from another
client.
Set a value for the dedicated SMB receiving buffer memory
capacity from 64 to 1024 KB, in 32 KB increments.
•
Memory Spool:
When selected, the machine will use
spooling. The receiving buffer for spooling uses memory.
When this candidate value is selected, set the memory
capacity of the receiving buffer for spooling from 0.50 MB to
32.00 MB, in 0.25 MB increments.
NOTE: Notice that print data exceeding the set memory
capacity is not accepted. In such cases, select Hard Disk or
Off.
•
Hard Disk Spool:
When selected, the machine will use
spooling. The receiving buffer for spooling uses the hard disk.
Receiving Buffer - IPP
Spool
•
Off:
When Off is selected, the machine will not use spooling.
While IPP print processing is being carried out for one client,
data cannot be received over the same interface from another
client. Set a value for the dedicated IPP receiving buffer
memory capacity from 64 to 1024 KB, in 32 KB increments.
•
Hard Disk:
When selected, the machine will use spooling.
The receiving buffer for spooling uses the hard disk.