3/99
General Procedures/Information
5-50
Xerox DocuPrint N17 Service Manual
Figure 5.2.1.20.1 Test Point Locations
7 Press the ENTER key to execute the test. The LCD displays the HVPS (C. ROLL AC) message.
NOTE: Voltage is present for approximately one second each time the Enter key is pressed to execute
the test.
8 The normal momentary output voltage to the Charge Roll is approximately 820 VAC.
9 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
10 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
HVPS (C. ROLL AC)
Operation EXECED