RUDICS Tunnel Setup
The setup of the RUDICS template and tunnels in the template depend on the user. A general
layout is below:
S
ETUP OF A
RUDICS
TUNNEL USING A
C
OMMERCIAL
SIM.
Setup Specifics – Main setup
Enabled
Allow the Tunnel to function
Site Name
Name your tunnel anything you want (you’ll want to make it easy to
find)
Iridium Listen Port
Assigned by Xeos; the SIM card must be provisioned to
XeosOnline’s IP and this Port (Supplied to customer if through
another Iridium provider)
Connect Script
Allow script to be used to download data
Alternate Script
Filename
Script for downloading data
IMEI
Device to which the tunnel is associated
Setup Specifics – Individual Tunnels
Checkbox
Enable/Disable this individual tunnel
Name
Name the tunnel what you want
Local Port
The port used to make the connection via XeosOnline to the
peripheral device
assigned by Xeos.
Remote IP
IP address of the device connected to the Xi-100b
Remote Port
Choose an appropriate port for the device connected to the Xi-100b
Protocol
TCP or UDP where appropriate
Delete
Delete this tunnel
Once all settings are input, click “Save Tunnel” on the bottom of this window.
Содержание Alert Geomatics Xi-100b
Страница 1: ...Xi 100b User Manual GLOBAL SATELLITE TRANSCEIVER Version 4 1 April 2019...
Страница 25: ...A 05 018 1 Xi 100b Port 1 Power Supply External Sensor DB9...
Страница 26: ...Xi 100b User Manual Version 4 1 2 A 05 018 3 Xi 100b Port 1 Power Supply...
Страница 27: ...Xi 100b User Manual Version 4 1 3 A 05 019 1 Xi 100b Port 2 Ethernet RJ45 Serial DB9...
Страница 28: ...Xi 100b User Manual Version 4 1 4 A 05 019 2 Xi 100b Port 2 Q330 Serial QNet...
Страница 29: ...Xi 100b User Manual Version 4 1 5 A 05 019 4 Xi 100b Port 2 Q330 Serial Ethernet RJ45...
Страница 30: ...Xi 100b User Manual Version 4 1 6 A 05 019 5 Xi 100b Port 2 Q330 Serial...
Страница 31: ...Xi 100b User Manual Version 4 1 7 A 05 027 Xi 100b Port 2 Xi 100b Programming Cable DB9...
Страница 32: ...Xi 100b User Manual Version 4 1 8 A 05 028 Xi 100b Port 2 Q330 QNet...