Terminal Configuration
M370046-01
5-21
5
Multichannel
Address Setting
The power supply multichannel address can be set to any address between
1 to 30. All units that are connected together via the RS-232 or RS-485
connector must have a unique multichannel address.
To set the address:
1. Select the appropriate communication port as described “Selecting
the Appropriate Communication Port” on page 5–20.
If more than one unit has the same multichannel address when
connected through the RS-485 connector, then collisions are possible,
resulting in garbled responses to queries.
2. Press the Rotary knob/Enter button.
ADDR
is displayed on the output voltage display.
3. Turn the Rotary knob/Enter button to select the desired multichannel
address
between 1 to 30.
4. Press the Rotary knob/Enter button to commit the new address.