background image

About Xantrex

Xantrex Technology Inc. is a world-leading supplier of advanced 
power electronics and controls with products from 50 watt mobile 
units to one MW utility-scale systems for wind, solar, batteries, fuel 
cells, microturbines, and backup power applications in both grid-
connected and stand-alone systems. Xantrex products include 
inverters, battery chargers, programmable power supplies, and 
variable speed drives that convert, supply, control, clean, and 
distribute electrical power.

Trademarks

XPower by Xantrex is a trademark of Xantrex International. 
Xantrex is a registered trademark of Xantrex International.
Other trademarks, registered trademarks, and product names are the 
property of their respective owners and are used herein for 
identification purposes only.

Notice of Copyright

XPower Pocket Inverter 175 Owner’s Guide
© October 2005 Xantrex International. All rights reserved.

Disclaimer

UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX 
TECHNOLOGY INC. (“XANTREX”)

(a)

MAKES NO WARRANTY AS TO THE ACCURACY, 

SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER 
INFORMATION PROVIDED IN ITS MANUALS OR OTHER 
DOCUMENTATION.

XPower_pocket_inv_175.book  Page i  Wednesday, October 26, 2005  3:26 PM

Содержание XPower Pocket Inverter 100

Страница 1: ...XPower by Xantrex is a trademark of Xantrex International Xantrex is a registered trademark of Xantrex International Other trademarks registered trademarks and product names are the property of their...

Страница 2: ...UT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Date and Revision October 2005 Revision B Part Number 975 0237 01 01 Contact Information Phone 1 3...

Страница 3: ...with Cigarette Lighter Plug 10 Using the DC Cable with Airplane Power Plug 12 Airline Compatibility 13 6 Inverter Operation 14 Operating Guidelines 14 Battery Operating Time 16 Interference with Elect...

Страница 4: ...Specifications 21 AC Power Output 21 USB Power Output 21 DC Power Specifications 22 Physical Specifications 22 9 Warranty and Return 23 XPower_pocket_inv_175 book Page iv Wednesday October 26 2005 3 2...

Страница 5: ...t and USB port The XPower inverter uses reliable solid state power electronics for years of safe trouble free operation and includes automatic safety monitoring circuitry to protect it and your batter...

Страница 6: ...2 Troubleshooting information page 18 Specifications page 21 Warranty and service information page 23 XPower_pocket_inv_175 book Page 2 Wednesday October 26 2005 3 26 PM...

Страница 7: ...ments in the guide Warnings identify conditions that may result in personal injury or loss of life Cautions identify conditions or practices that may damage the unit or other equipment Warnings and Ca...

Страница 8: ...use the XPower inverter in the presence of flammable fumes or gases such as in the bilge of a gasoline powered boat or near propane tanks Do not use the XPower inverter in an enclosure containing auto...

Страница 9: ...e AC outlet a bent prong can slip outside the inverter and become a shock hazard WARNING Shock hazard Grip the inverter carefully when inserting or removing an AC plug Keep your fingers clear of the A...

Страница 10: ...rectly into an AC receptacle to recharge Battery chargers used in hand power tools These chargers display a warning label stating that dangerous voltages are present at the charger battery terminals C...

Страница 11: ...distribution wiring Do not use the XPower inverter in temperatures over 100 F 40 C Do not expose the XPower inverter to water rain snow or spray Failure to follow these safety guidelines may cause per...

Страница 12: ...overload protection with automatic shutdown User replaceable 20 A fuse Low battery voltage shutdown High input voltage protection with automatic shutdown Overheat protection with automatic shutdown Ou...

Страница 13: ...ories Airplane power plug AC outlet Power Fault light Fuse Cigarette lighter plug adapter USB power port DC cable port Ventilation openings DC Cable Pocket Inverter 175 Accessory bag XPower_pocket_inv...

Страница 14: ...imilarly to the sine wave shape of utility power Using the DC Cable with Cigarette Lighter Plug Due to the limitations of 12 V outlets in vehicles or boats the XPower inverter should only be used to s...

Страница 15: ...outlet to prevent slight discharge of the battery CAUTION Reverse polarity damage When plugging in the DC cable ensure that the plug aligns with the DC cable port Failure to do so will result in reve...

Страница 16: ...wer plug into the 12 V outlet 3 Plug the device you want to operate into the XPower inverter See Inverter Operation on page 14 CAUTION Reverse polarity damage When plugging in the DC cable ensure that...

Страница 17: ...747 400 Business Class Air France A330 200 1st Class Business American DC 10 1st Class Business American 727 200 737 800 767 300 MD 80 MD 11 All Classes Cathay Pacific 747 400 777 200 A330 All Classes...

Страница 18: ...dropped to 10 5 V the inverter automatically shuts down and the light glows red indicating a fault This prevents the battery from being damaged Turn off any devices that the XPower inverter is powerin...

Страница 19: ...ght comes on Should a defective battery charging system cause the battery voltage to rise to dangerously high levels the XPower inverter automatically shuts down The red fault light comes on In the ev...

Страница 20: ...recommended to start the vehicle every hour or two to recharge the battery before its capacity drops too low The XPower inverter can operate while the engine is running but the normal voltage drop th...

Страница 21: ...o minimize its interference with TV signals However with weak TV signals interference may be visible in the form of lines scrolling across the screen The following should minimize or eliminate the pro...

Страница 22: ...connections Check connections Fuse is blown Replace fuse see page 20 Possible cause Remedy Standard average reading AC voltmeter used to measure output voltage resulting in an apparent reading 5 to 15...

Страница 23: ...er rating high starting surge has caused overload shutdown Product exceeds inverter s surge capability Use a product with starting surge power within the inverter s capability Battery is discharged Re...

Страница 24: ...inverter has a replaceable 20 A fuse Remove the blown fuse from the back of the unit and replace it with a Littelfuse Mini fuse Littelfuse catalog number 0297 020 XPower_pocket_inv_175 book Page 20 W...

Страница 25: ...oltage nominal 120 V AC Continuous AC output power 140 W 5 minutes AC output power 175 W Maximum AC output surge power 280 W AC output frequency 60 1 Hz AC output waveform Modified sine wave DC output...

Страница 26: ...at 12 V input 0 25 A Efficiency maximum 90 Low battery shutdown point nominal 10 5 V High battery shutdown point nominal 15 5 V Ambient operating temperature range 0 C 40 C 32 F 104 F Dimensions L W...

Страница 27: ...rovided that you notify Xantrex of the product defect within the Warranty Period and provided that Xantrex through inspection establishes the existence of such a defect and that it is covered by this...

Страница 28: ...es and Canada Alaska and Hawaii are excluded Contact Xantrex Customer Service for details on freight policy for return shipments outside of the contiguous United States and Canada How do you get servi...

Страница 29: ...dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex Proof of purchase may be in any one of the...

Страница 30: ...b the product if it has been subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the...

Страница 31: ...RER S LIABILITY OPERATION OF LAW CONDUCT STATEMENT OR OTHERWISE INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ANY IMPLI...

Страница 32: ...o the extent permitted by applicable law they are limited to the duration of this Limited Warranty Some states and provinces do not allow limitations or exclusions on implied warranties or on the dura...

Страница 33: ...NTATIONS OR WARRANTIES REGARDING THE USE OF THE XANTREX XPOWER INVERTER IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES Please note that the XPower inverter is not intend...

Страница 34: ...thout an RMA number clearly marked on the outside of the shipping box if they are shipped collect or if they are shipped to the wrong location When you contact Xantrex to obtain service please have yo...

Страница 35: ...he outside of the box A return address where the unit can be shipped Post office boxes are not acceptable A contact telephone number where you can be reached during work hours A brief description of t...

Страница 36: ...no dated proof of purchase is available your inverter may be serviced or replaced for a flat fee To return your XPower inverter for out of warranty service contact Xantrex Customer Service for a Retur...

Отзывы: