
4
BATTERY OPERATION
Please read this section for safety information and operational
instructions regarding your XPLORE Charger. This section
includes:
Input Voltage Operating and Derating
Input Voltage Operating and
Derating
When AC input is within the lower range between 90–108 VAC,
the XPLORE Charger derates to 80% of maximum current.
However, when AC input increases above 108 VAC up to
265 VAC, maximum current returns to 100% capacity.
Furthermore, the XPLORE Charger will continue to operate at
100% of maximum current.
Dual Chemistry Charging
The XPLORE Charger allows either Group 1 or Group 2 to charge
batteries of a different chemistry. The outputs share the full rated
current enabling it to charge two different battery kinds and can
tolerate the same charge sequence and thresholds.
NOTE
: The battery banks are not galvanically isolated from each
other. They share a common negative as shown in
.
The negative bus to DC neg(-) bus connection as shown below
may not be suitable in some applications.
975-1038-01-01
31
Содержание XPLORE 120/12
Страница 1: ...XPLORE 120 12 Battery Charger Owner s Guide Model XPLORE 120 12 Battery Charger 819 0120 12...
Страница 16: ...This page is intentionally left blank 2...
Страница 22: ...This page is intentionally left blank 2...
Страница 42: ...This page is intentionally left blank 2...
Страница 56: ...This page is intentionally left blank 2...
Страница 68: ...975 1038 01 01 Rev A 30996 http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...