110W Solar Max Flex Panel

Model Number: 784-0110

110W Solar Max Flex Slim Panel

Model Number: 784-0110S

220W Solar Max Flex Panel

Model Number: 784-0220

330W Solar Max Flex Panel

Model Number: 784-0330

NOTE

: Actualproduct may be different from what is shown.

Thank you for purchasing the Xantrex Solar Max Flex Panel. The Xantrex Solar Max Flex Panel is a
high quality, carbon emissions-free, and sustainable power source for your vehicle such as,
recreational vehicle (RV), truck, or boat. It is designed to take solar energy and quietly produce power
for your vehicle's DC appliances and store energy to a battery during daylight hours.

The Solar Max Flex Panel base package includes the
following items:

n

one Solar Max Flex Panel

n

one Product Notice with a link to this Installation
Guide

NOTE

: If any of the accessories, materials, and other

items are missing, contact Xantrex or any authorized
Xantrex dealer for replacement. See

Contact Information

on the back cover.

The following Xantrex accessories are available to complete your solar system and are sold
separately:

n

Solar and Battery Cables Starter Kit (PN: 708-0150)

n

PWM 30A Charge Controller (PN: 709-3024-01)

n

MPPT 30A Charge Controller (PN: 710-3024-01)

n

MPPT Remote Display (PN: 710-0010)

Содержание SOLAR 784-0110

Страница 1: ...energy and quietly produce power for your vehicle s DC appliances and store energy to a battery during daylight hours The Solar Max Flex Panel base package includes the following items n one Solar Max...

Страница 2: ...t disassemble the solar max flex panel except where noted for connecting wiring and cabling See your warranty for instructions on obtaining service Attempting to service the solar max flex panel yours...

Страница 3: ...c Installation Steps 6 Safety Instructions 6 Tools and Materials 6 Solar Panel Wiring 11 Solar Panel Maintenance and Care 13 Troubleshooting 14 Specifications 14 Accessory List 16 975 1029 01 01 Rev B...

Страница 4: ...This page is intentionally blank...

Страница 5: ...codes and regulations n Disconnect all power sources n Disable and secure disconnect devices Failure to follow these instructions can result in death serious injury or equipment damage Tools and Mater...

Страница 6: ...that is readily accessible viewable and free from exposure to moisture c Plan the route and measure the lengths of cables needed to reach their connection points factoring in bends and slack d You may...

Страница 7: ...an obstruct direct exposure to sunlight l Select the mounting area carefully and mark the exact and intended location of the solar panel Failure to follow these instructions can result in physical dam...

Страница 8: ...t the 3M website Figure 4 Adhesive placement depending on surface sealing tape Forillustration purposes The solarcellsare shown asperspective only Do not applythe adhesive tape on top of the solarcell...

Страница 9: ...ute the PV cables through the roof entry point and connect the red pos and black neg PV cables to the charge controller See T3 d Connect the red pos and black neg battery cables to the charge controll...

Страница 10: ...power point tracking 30A 12 24VDC 710 3024 01 b Solar panels can be configured in series parallel or a combination of both series and parallel Figure 5 Cable schematic for series Pos of first panel c...

Страница 11: ...first panel connects to Neg of next panel using branch connectors and so on and terminating with the Neg of the solar charge controller Optimized for MPPT or PWM solar charger Figure 7 Cable schematic...

Страница 12: ...he amount of sunlight that reaches the solar cells Therefore any build up of dust or dirt on the surface of the solar panel will result in a loss of power This is a trade off between the maximizing th...

Страница 13: ...light Loose or no DC cable connections Connect DC cables to the battery and solar panel and tighten terminal connections Fuse is blown Replace the blown fuse with a 30A 32V green ATC blade fuse Specif...

Страница 14: ...220 W Maximum power voltage 24 6 V Maximum power current 9 0 A Open circuit voltage 29 2 V Short circuit current 9 7 A Maximum system voltage 600 VDC Safety Class II PV Module Insulate leads and conn...

Страница 15: ...50 PV Connector Assembly Tool PN 708 0060 Mounting Hardware PN 708 0070 Remote Battery Temperature Sensor PN 708 0080 Roof Entry Cable Plate PN 708 0090 Solar and Battery Cables Starter Kit 10 AWG 20...

Страница 16: ...1 800 670 0707 1 408 987 6030 customerservice xantrex com http www xantrex com power products support http www xantrex com 975 1029 01 01 Rev B June 2022 Printed in USA...

Страница 17: ...produire silencieusement de l nergie pour les appareils CC de votre v hicule et stocker de l nergie dans une batterie pendant la journ e Le pack de base le panneau solaire Max Flex comprend les l ment...

Страница 18: ...connect vos syst mes lectriques CC Le fabricant recommande que tout le c blage soit effectu par un technicien PV ou un lectricien agr pour assurer le respect des codes lectriques locaux et nationaux...

Страница 19: ...MATION L UTILISATION D UNE TELLE INFORMATION SE FAITAUX SEULS RISQUES DE L UTILISATEUR ET C VOUS RAPPELLE QUE DANS LE CAS O CE MANUEL SERAITR DIG DANS UNE LANGUE AUTRE QUE L ANGLAIS ETBIEN QUE TOUTES...

Страница 20: ...Cette page est intentionnellement vide...

Страница 21: ...de base 24 Consignes de s curit 24 Outils et mat riaux 24 Panneau solaire c blage 29 Maintenance et entretien des panneaux solaires 31 D pistage des anomalies 32 Fiche technique 32 Liste d accessoire...

Страница 22: ...Cette page est intentionnellement vide...

Страница 23: ...r et d brancher les appareils de fa on s curitaire N gliger de suivre ces directives risque de causer des dommages l quipement de graves blessures voire la mort Outils et mat riaux Vous aurez besoin d...

Страница 24: ...ne zone facilement accessible visible et l abri de l humidit c D terminez le trac et la longueur de c ble n cessaire pour atteindre leurs points de connexions en tenant compte des coudes et du jeu d V...

Страница 25: ...toit qui risquent d obstruer l exposition la lumi re directe du soleil l Choisir soigneusement la zone de montage et marquer avec pr cision l endroit pr vu pour le panneau solaire N gliger de suivre c...

Страница 26: ...ons allersurle site 3M Figure 4 Le placement de l adh sif d pend de la surface bande d tanch it desfinsd illustration Lescellulessolairessont vuesen perspective uniquement N appliquezpasle ruban adh s...

Страница 27: ...r les passe c bles du toit et connectez les c bles PV positif rouge et n gatif noir au contr leur de charge Consultez T3 d Connectez les c bles de batterie positif rouge et n gatif noir au contr leur...

Страница 28: ...nt de puissance maximum MPPT 30A 12 24VCC 710 3024 01 b Les panneaux solaires peuvent tre configur s en s rie en parall le ou une combinaison des deux en s rie et en parall le Figure 5 Sch ma du c bla...

Страница 29: ...connecte au Neg du panneau suivant et ainsi de suite et se termine par le Neg du contr leur de charge solaire Optimis pour le chargeur solaire MPPT ou PWM Figure 7 Sch ma du c blage pour combinaison U...

Страница 30: ...ntit de lumi re solaire qui atteint les cellules solaires Par cons quent toute accumulation de poussi re ou de salet sur la surface du panneau solaire entra nera une perte de puissance Il s agit d un...

Страница 31: ...il Connexions de c ble CC desserr es ou inexistantes Connectez les c bles CC la batterie et au panneau solaire et serrez les connexions des bornes Le fusible est grill Remplacez le fusible grill par u...

Страница 32: ...n de puissance max 24 6 V Courant de puissance max 9 0 A Tension de circuit ouvert 29 2 V Courant de court circuit 9 7 A Tension syst me max 600 VCC S curit Module PV de classe II Isolez les c bles et...

Страница 33: ...mblage de connecteur PV NP 708 0060 Le mat riel de montage NP 708 0070 Sonde de temp rature de batterie distance NP 708 0080 C ble d entr e de toit NP 708 0090 Kit de d marrage de c bles solaires et d...

Страница 34: ...1 800 670 0707 1 408 987 6030 customerservice xantrex com http www xantrex com power products support http www xantrex com 975 1029 02 01 R v B Juin 2022 Printed in UA...