Side Panel
975-0822-01-01
9
Side Panel
1
2
4
3
Figure 4 Side Panel
WARNING
ELECTRICAL SHOCK HAZARD
n
Use a torque screwdriver to tighten the captive nut panel
screw to 0.56 N-m torque to ensure a proper earth
connection and a required tool access to the wiring
compartment.
n
Use a torque screwdriver to tighten the bolt on the DC
earth lug to a torque of 2.6 N-m of force.
n
Apply an anti-corrosion compound to the copper wire prior
to connecting to the DC earth lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Item
Description
1
Captive nut panel screw
holds the wiring compartment
cover in place. See WARNING above.
2
Wiring compartment cover
protects the wiring
compartment from debris and keeps the cables secure.
Using the captive nut panel screw, the cover can be
opened and lifted out during wiring. See WARNING on the
left.
3
c
Reserved for future use.
Supplementary protector
with reset button.
4
Earthing lug
provides an earth path for the Freedom X
chassis to the DC system earth. See WARNING.
Table 3 Side Panel Features