Troubleshooting
Fault Types
There are three types of fault messages: automatic faults, manual
faults, and escalating automatic faults. Table 3 describes how they
differ in their behavior and how you can respond to them when they
appear on the SCP.
Table 1
Fault Types And Behaviors
Fault type
Behavior
Automatic faults
Clear automatically if the fault condition that generated the
message goes away. You can also acknowledge automatic
faults without waiting for them to clear automatically.
Manual faults
Require you to clear them by:
•
selecting Clear Faults on the Main Freedom SW 230V
menu or on the menu for the Xanbus-enabled device
that generated the fault (if the fault condition still exists,
the fault message reappears)
•
correcting the condition that caused the fault.
Escalating
automatic faults
Clear automatically if the fault condition goes away, just like
an automatic fault.
However, if an escalating automatic fault occurs several
times within a defined time period, the escalating automatic
fault becomes a manual fault, requiring user intervention.
For example, if an AC Overload fault occurs three times in
five minutes, it will no longer clear itself and become a
manual fault. Then you must identify the problem, correct
the fault condition, and clear the fault.
FSW 230V Owners Guide.book Page 73 Tuesday, August 7, 2018 9:38 AM
Содержание Freedom SW 230V 815-3524-02
Страница 2: ...FSW 230V Owners Guide book Page ii Tuesday August 7 2018 9 38 AM...
Страница 10: ...FSW 230V Owners Guide book Page viii Tuesday August 7 2018 9 38 AM...
Страница 14: ...FSW 230V Owners Guide book Page iv Tuesday August 7 2018 9 38 AM...
Страница 98: ...FSW 230V Owners Guide book Page 84 Tuesday August 7 2018 9 38 AM...
Страница 103: ...FSW 230V Owners Guide book Page i Tuesday August 7 2018 9 38 AM...