Adjusting Settings in Configuration Mode
975-0999-01-01
35
Charger Sub-settings
Setting Name
Setting
Number
Default
Value
Range of Values
Unit Step
Description
Battery Type
C1
FLD
FLD
(Flooded),
GEL
(Gel),
USE
(Custom),
LFP
(LiFePO
4
),
AGn
(AGM),
--
--
Sets the corresponding battery type to the
actual battery used in the power system.
LFP
(LiFePO
4
) is a pre-set battery type that
requires a compatible Xantrex Battery with
BMS. Other lithium-ion batteries with BMS
should be set as
USE
(Custom) battery type
with parameters set according to the battery
manufacturer's specifications.
Battery Capacity
C2
10
0
to
300
Ah
1 (0
to
10)
10
(10-
300)
Sets the battery capacity of the system. The
value displayed must be multiplied by a factor
of 10 for the real value. For example, the
default 100Ah is displayed as
10
, 1200Ah will
show as
120
, 10Ah will show as
1
.
Maximum Charge
Current
C3
80
4
to
80
A
1
Sets the maximum DC output current that is
available to the charger.