Basic Installation Procedures
975-0998-01-01
23
Figure 8 50 A Service to 50 A RV Electrical System
L1
L2
G
N
L1
L2
G
N
20A
20A
J
K
L
G
E
A
C
B
D
F
H
I
20A
15A
15A
20A
15A
15A
20A
20A
20A
20A
SHORE
INVERTER LOAD
c
For illustration
purposes only. Not all
electrical connections
are shown.
The □ icon is a
circuit-breakered
main line connection
to the line bus.
A
AC Input terminals
E
Vehicle's AC Shore
Distribution Panel
I
50A RV/Vessel Inlet
Receptacle
B
AC Output terminals
F
Vehicle's AC Inverter
Distribution Panel
J
50A AC Load (split
120/240 VAC in, passthrough
mode only). No power in
inverter mode for 240 VAC
C
AC Input wires L1|N|L2|G
G
Power Distribution Panel
with 20A, 30A, and 50A
standard outlets
K
20A AC Load (120 VAC) on
L1 (inverter and passthrough
modes)
D
AC Output wires L1|N|L2|G
H
RV 50A Shore Power
Extension Cord
L
20A AC Load (120 VAC) on
L2 (inverter and passthrough
modes)
c
Shore Power Distribution Panel outlets vary in different locations.
Figure 9 30A Service to 50A RV Electrical System
J
K
L
M
I
H
L1
L2
G
N
L1
L2
G
N
G
E
A
C
B
D
F
20A
15A
15A
20A
15A
15A
30A
20A
20A
20A
20A
SHORE
INVERTER LOAD
20A
20A
c
For illustration
purposes only. Not all
electrical connections
are shown.
The □ icon is a
circuit-breakered
main line connection
to the line bus.
A
AC Input terminals
E
Vehicle's AC Shore
Distribution Panel
I
RV 50A Shore Power
Extension Cord
B
AC Output terminals
F
Vehicle's AC Inverter
Distribution Panel
J
50A RV/Vessel Inlet
Receptacle
C
AC Input wires L1|N|L2|G
G
Shore Power Distribution
Panel with 20A and 30A
standard outlets
K
50A AC Load (single-phase
120 VAC). No power in
inverter and passthrough
modes for 240 VAC
D
AC Output wires L1|N|L2|G
H
Dog Bone RV/Electrical
Adapter 50A Female to 30A
Male
L
20A AC Load (120 VAC) on
L1 (inverter and passthrough
modes)
c
Shore Power Distribution Panel outlets vary in different locations.
M
20A AC Load (120 VAC) on
L2 (inverter and passthrough
modes)
Figure 10 30A Service to 30A RV Electrical System
J
I
H
L1
L2
G
N
L1
L2
G
N
G
E
A
C
B
D
F
30A
20A
15A
15A
20A
15A
15A
30A
20A
20A
SHORE
INVERTER LOAD
20A
c
For illustration
purposes only. Not all
electrical connections
are shown.
The □ icon is a
circuit-breakered
main line connection
to the line bus.
A
AC Input terminals
E
Vehicle's AC Shore
Distribution Panel
I
30A RV/Vessel Inlet
Receptacle
B
AC Output terminals
F
Vehicle's AC Inverter
Distribution Panel
J
20A AC Load (120 VAC)
C
AC Input wires L1|N|G
G
Shore Power Distribution
Panel with 20A and 30A
standard outlets
c
Shore Power Distribution
Panel outlets vary in different
locations.
D
AC Output wires L1|N|G
H
RV 30A Shore Power
Extension Cord
For information on stacking two Freedom EX 4000 units in
series to form a split-phase 120/240 VAC inverter power system
in Battery mode, see
. For
information on stacking two Freedom EX 4000 units in parallel
to double inverting and charging capacity in Battery mode, see
Содержание Freedom EX 4000
Страница 8: ...This page is intentionally left blank 2...
Страница 10: ...This page is intentionally left blank 1...
Страница 51: ...This page is intentionally left blank 2...