AC and DC Panel
6
Freedom X 2000 - 230V Owner's Guide
AC and DC Panel
6
3
2
1
7
14
13
12
13
8
11
9
10
4
5
5
12
15
Figure 2 AC and DC Panel
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the captive nut panel screw to
0.56 N-m torque of force to ensure a proper earth connection and a
required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Item
Description
1
ACC input terminal
for connecting ignition control wiring.
Ignition Control Switch (ACC) for connecting [ON (|)] and
disconnecting [OFF (O)] the ignition signal.
2
Remote port
allows you to connect an accessory remote
control / display device.
3
Captive nut panel screw
holds the wiring compartment
cover in place. See WARNING above.
4
Ventilation grille
(openings) must not be obstructed.
5
Earthing lug
provides an earth path for the Freedom X
chassis to the DC system earth. See WARNING.
6
DC terminal
opening for routing (–) negative DC cable.
Table 1 AC and DC Panel Features