Basic Installation Procedures
975-1057-01-01
40
Step 4: Connecting the DC Cables
DC Connection Precautions
DANGER
ELECTRICAL SHOCK DAMAGE
Connect and disconnect DC wiring only after opening the
disconnect switches or breakers at all AC and DC sources.
Failure to follow these instructions can damage the unit and/or
damage other equipment.
Recommended Cable Sizes and Lengths
and Fuse Size
For recommended DC cables and fuse sizes, see
and
Recommended Fuse Size on page 27
Preparing the Cables
To prepare the DC cables:
1. Cut the negative and positive cables to the required length.
Strip off enough insulation so you can install the terminals
you will be using.
It is recommended to use crimp connectors. The connector
should be designed for a 3/8" (9.4mm) stud size to connect
to the Freedom SW-RVC. If a crimp connector is used, it
should be crimped using the tool indicated by the connector
manufacturer.
2. Cut the DC ground cable to the required length. Strip off
enough insulation so you can install the terminals you will
be using.
It is recommended to use crimp connectors. The connector
should be designed for a 1/4" (6.35mm) stud size to connect
to the Freedom SW-RVC. If a crimp connector is used, it
should be crimped using the tool indicated by the connector
manufacturer.
3. Attach the connectors to the ends of both cables. Make
sure no stray wire strands protrude from the connectors.