manualshive.com logo in svg
background image

Xantrex AC to DC 
Converter

Manual Type

40 A (XADC-40)
60 A (XADC-60)
80 A (XADC-80)

Owner’s Guide

Towable-OEM-40-60-80A.book  Page i  Monday, March 5, 2007  12:15 PM

Содержание 40 A (XADC-40)

Страница 1: ...Xantrex AC to DC Converter Manual Type 40 A XADC 40 60 A XADC 60 80 A XADC 80 Owner s Guide Towable OEM 40 60 80A book Page i Monday March 5 2007 12 15 PM...

Страница 2: ...Towable OEM 40 60 80A book Page ii Monday March 5 2007 12 15 PM...

Страница 3: ...Xantrex AC to DC Converter Owner s Guide Towable OEM 40 60 80A book Page i Monday March 5 2007 12 15 PM...

Страница 4: ...March 2007 Xantrex International All rights reserved Exclusion for Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICI...

Страница 5: ...bleshoot the XADC Organization This Guide is organized into two chapters and one appendix Features Chapter 1 introduces the Xantrex AC to DC Converter shows where the major components are and lists th...

Страница 6: ...he XADC 80 when it is being referenced individually When the Xantrex XADC 40 XADC 60 and XADC 80 are being referenced together they will be referred to as the XADC Related Information You can find mor...

Страница 7: ...ction 5 Do not disassemble the XADC It contains no user serviceable parts and attempting to service it will void your warranty See Warranty for instructions on obtaining service Attempting to service...

Страница 8: ...arts and could cause an explosion 5 Remove all metal items like rings bracelets and watches when working with lead acid batteries Lead acid batteries produce a short circuit current high enough to wel...

Страница 9: ...o provide reasonable protection against harmful interference when the equipment is operated in a residential environment This equipment generates uses and can radiate radio frequency energy and if not...

Страница 10: ...C DC Distribution Panel 2 2 Operation and Troubleshooting Switching the XADC On and Off 5 Maintenance 5 Troubleshooting Reference 6 A Specifications Mechanical Specifications 7 Electrical Performance...

Страница 11: ...n Panel Special Features The XADC has many convenient features Current limiting over temperature protection input under voltage protection and input over voltage protection to give you worry free safe...

Страница 12: ...A Part Number 810 0030 00 XADC P30 eight output breakers 50A Part Number 810 0050 00 XADC P50 10 output breakers In each configuration there are also 11 unassigned DC fuses and four reserved fuses for...

Страница 13: ...designation label 3 Removable AC DC Distribution Panel faceplate service technician only 4 AC breakers not included 5 Screw for removing AC DC panel faceplate service technician only 6 Screw for remo...

Страница 14: ...4 Towable OEM 40 60 80A book Page 4 Monday March 5 2007 12 15 PM...

Страница 15: ...C loads should be Littelfuse Type 257 or equivalent and the maximum allowed fuse for the DC loads is 20 A Breakers for the AC side should be MAIN Cutler Hammer Bryant Westinghouse Type BR Series and I...

Страница 16: ...are damaged or not installed AC input breaker open Short circuit in one or more of the load circuits Internal temperature too hot Something may be preventing the fan from turning The unit has a safet...

Страница 17: ...nit may shut down Length 11 13 16 in 300 0 mm Width 7 1 8 in 180 0 mm Height 4 3 4 in 120 0 mm AC Input XADC 40 XADC 60 XADC 80 Input current at rated output 6 Aac 9 Aac 12 Aac Nominal input voltage 1...

Страница 18: ...credit card or money order will be explained by the Customer Service Representative In cases where the minimum flat fee does not apply as with incomplete units or units with excessive damage an additi...

Страница 19: ...Towable OEM 40 60 80A book Page 9 Monday March 5 2007 12 15 PM...

Страница 20: ...Xantrex Technology Inc www xantrex com 975 0305 01 01 Printed in China Towable OEM 40 60 80A book Page 10 Monday March 5 2007 12 15 PM...

Отзывы: