![Xantech 794 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/xantech/794/794_installation-instructions_3164952001.webp)
1
Modules & Connecting Blocks
INSTALLATION INSTRUCTIONS
794 & 797
INTERFACE MODULES
The Model 794 or 797 allows any of the Xantech 3-wire IR receivers, keypads and control systems to
connect directly to the serial remote control input jack found on many audio/video components. This
eliminates the need for attaching an emitter to the front panel of the unit. The installer, by choosing the
correct model number, suffix number and DIP switch settings, may use these modules to control many
components.
INSTALLATION
• Review all tables 1, 2, & 3 to make sure you select the correct interface. The model number suffix generally
specifies which INTERFACE CABLE is supplied with the unit (see Tables 1, 2 & 3).
•
Do Not
extend the cable supplied with the 794 or 797. The unit may not operate reliably when a longer
cable is used.
•
Do Not
plug the 794 or 797 into anything until all switches are set.
• There are ten DIP switches on the 794 and two on the 797. When the 794 or 797 is driven by a Model
390 Blast-IR or Model 792 Power Module, switch
S1
must be in the
0
(off) position.
• The 794 and 797 are designed to supply power to Xantech 3-wire IR Receivers and keypads. Connect
them directly to the
IN
,
GND1
and
+12V
terminals. The
IN
and
GND1
terminals may also be connected
to any Xantech emitter output port.
• Use a 781RG or 782-00 power supply to power the 794 and 797 by plugging them into the
+12V
jack.
You may also power them from other Xantech devices in a system by r12 V and Gnd jumper leads
from the other device to the
+12V
and
GND2
terminals on the 794 and 797.
• If the plug on the 781RG or 782 power supply does not fit the
+12V
jack on the 794 or 797, simply remove
the plug and connect the white striped wire to
+12V
and the black wire to
GND2
on the 794 or 797
terminals.
MODEL 794
• Switch
S3
should be in the
1
(on) position in most
installations.
• When multiple 794’s are connected, or when ground
loops are encountered, set
S3
to the
0
(off) position.
• Switch
S2
, and
S4
through
S10
, should be set ac-
cording to Table 1, page 2. For products not listed,
contact Xantech Technical Support. New versions
are added from time to time.
MODEL 797
• Switch
S2
should be in the
1
(on) position in most
installations. When multiple 797’s are connected or
when ground loops are encountered, set
S2
to the
0
(off) position.
• In general, set
S1
and
S2
according to Table 2, next
page. For products not listed, contact Xantech Tech-
nical Support. New versions are added from time to
time.
OUTPUT
+12V
IR IN
GND1
GND2
+12V
1 (ON)
0 (OFF)
1 2 3 4 5 6 7 8 9 1 0
ON
SENDER/
EMITTER
1 2 3 4 5 6 7 8 9 10
794
UNIVERSAL INTERFACE
Fig. 1
794-00
IR IN
GND1
GND2
+12V
OUTPUT
+12V
1 (ON)
0 (OFF)
SENDER/
EMITTER
1 2
1 2
ON
797
SERIES
UNIVERSAL INTERFACE
Fig. 2
797-00