  792-10  Power Module

The 792-10 is a multipurpose device designed for use in the
following applications:

1. As an output amplifier and power source to convert

Xantech 3-wire IR Receivers to 2-wire PHANTOM
POWER operation.

2. As an output amplifier for any Xantech IR Receiver or

Controller to drive large numbers of emitters when
plugged into one or more 790-00 passive Connecting
Blocks.

FEATURES AND SPECIFICATIONS

• Phantom Power and/or Current booster modes.

• Phantom mode powers the 291-10, 480-00, 490 and 780-10 series IR receivers for 2-wire operation.

• Screw terminals provide for wired input connections.

• 3.5 mm mono mini jack emitter IR OUT port.

• Low current mode drives up to 4 emitters in series.

• High current mode drives up to 100 emitters in parallel through 790-00 Connecting Blocks.

• Maximum peak output current - Low Current mode: 100 mA.

• Maximum peak output current - High Current mode: 1 A.

• 2.1mm coaxial DC power jack (+12V).

• Requires a 781RG or a 782-00 power supply.

• Dimensions: 3-5/8" L x 1-5/8"  W x 1" D.

GENERAL

The input and output parameters for setting Normal 3-wire, Phantom 2-wire and Output Current modes are
configured by setting the DIP switches.  These switches are accessible through the slot in the case.

• In the Normal 3-Wire mode, +12V is applied to Xantech IR Receivers and Keypads on a third wire in the

same manner as on Xantech Connecting Blocks.

• In the Phantom 2-Wire mode, +12V is applied to the IR Receivers on the same wire that carries the IR

control signal.

PLEASE NOTE:  

The Xantech Smart Pads and the CFL Friendly IR receivers, will not operate with

the 2-wire Phantom Power connection!

• In the Low Current mode, the 792-10 IR OUT jack will drive a single or dual emitter or connecting blocks

in the same manner as an IR receiver.

• In the High Current mode the 792-10 IR OUT jack will drive up to 10 Model 790-00 Connecting Blocks,

each having up to ten emitters connected to it.

CAUTION:  

Do not plug single or dual emitters into the IR OUT jack when the 792-10 dip switches

are set to the High Current mode.  To do so will destroy emitters!