background image

©2007, X-Rite, Inc. 

Examolite

®

 and Prooflite

®

 

Overhead Luminaire 

OPERATION MANUAL

 

Part No. 17500030 Rev. B 

INTRODUCTION. 

The following products are described in this manual: 

Examolite TC-440B 

is an overhead luminaire that provides blended 

fluorescent daylight at 7500K. It is used for grading, sorting, and visual 
quality inspections. 

Examolite SD-840B 

is an overhead luminaire that provides simulated 

fluorescent Daylight (D75, D65, or D50), llluminant A (Incandescent), and 
cool white fluorescent (CWF). It is used for visual color evaluations, 
metamerism testing, and in applications where products need to be 
evaluated under multiple light sources. 

Prooflite PLD-440 

is an overhead luminaire that provides simulated 

fluorescent daylight (D75, D65, or D50). It is a 4-lamp, single source fixture 
typically used in viewing booth installations for visual color evaluations. 

Prooflite PLD-840 

is an overhead luminaire that provides simulated 

fluorescent daylight (D75, D65, or D50). It is an 8 lamp, single source 
fixture that provides higher levels of illumination for open room 
applications. A dual source fixture can also be achieved by combining four 
lamps of two different sources in one PLD-840 fixture. It is used for visual 
color evaluations. 

SAFETY INSTRUCTIONS

 

PLEASE READ AND FOLLOW INSTRUCTIONS—Follow all instructions before attempting installation and operation. 

KEEP INSTRUCTIONS—Retain these instructions for future reference. Once you have read these instructions, keep 
them available for other operators to read. 

OBEY ALL WARNINGS—Please comply with all warnings and safeguards in these instructions. They have been written 
to keep you and your fixture safe. 

CHOOSE PROPER POWER SOURCES—Use the proper power source. If you have any doubt, consult the label on the 
inside of the fixture for this information. 

NOT EXPLOSION-PROOF—This fixture is 

not 

explosion-proof and should 

not 

be used in a hazardous atmosphere with 

exposure to flammable substances. 

TURN OFF FIXTURE BEFORE CHANGING ANY LAMPS—Always turn off the fixture 

before you 

change lamps. 

Always turn off power before cleaning surfaces. 

ALLOW LAMPS TO COOL BEFORE TOUCHING THEM—Do 

not 

touch the hot lamps; allow them to cool. 

CLEAN PROPERLY—You can wipe the lamps and reflector with a clean, white lint-free cloth. Clean the diffuser and 
housing with a dampened cloth containing a mild soap. 

DO NOT OPERATE DURING LIGHTNING STORMS—As an added protection during a lightning storm, turn off the 
fixture so that it will 

not 

experience electrical power surges or unnecessary power drops that could result in damage to 

lamps and electrical circuitry. 

SERVICE PROPERLY—With the exception of lamp replacement, do 

not 

attempt to service this product yourself. If you 

should attempt unauthorized repairs, you may invalidate the warranty that is active on your fixture. For any other 
malfunctions in operation, contact X-Rite Technical Service. 

Содержание Examolite TC-440B

Страница 1: ...operation KEEP INSTRUCTIONS Retain these instructions for future reference Once you have read these instructions keep them available for other operators to read OBEY ALL WARNINGS Please comply with a...

Страница 2: ...ires are designed for 100VAC 50Hz 117VAC 60Hz 220VAC 50Hz 240VAC 50Hz or 277VAC 60Hz operation In all cases proper input power is marked on the box and fixture label CAUTION Do not operate fixture on...

Страница 3: ...cific electrical needs 6 If you are mounting the fixture into a standard grid ceiling follow the accepted mounting practices for your building code If the fixture is to be chain hung over a work surfa...

Страница 4: ...r Fixture Net Weights Proof lite PLD 4 lamp 57 5 lbs 25 87 kg Prooflite PLD 8 lamp 68 0 lbs 30 6 kg Examolite TC 440B 78 0 lbs 35 1 kg Examolite SD 840B 90 0 lbs 40 5 kg On the rear of the fixture hou...

Страница 5: ...PLD 840 Dual Source 2 Sets of 4 Fluorescent 4 Ballasts 2 Inputs Ballast 1 Lamps 1 and 3 Ballast 2 Lamps 2 and 4 Ballast 3 Lamps 5 and 7 Ballast 4 Lamps 6 and 8 Black leads for ballasts 1 and 3 go to...

Страница 6: ...is parallel to the longest side of the luminaire Replacement of Lamps Replace lamps at approximately 75 percent of their rated life expectancy to retain spectral characteristics Replace burned out lam...

Страница 7: ...incandescent lamps Dimensions Length 48 in 121 19 cm Width 23 75 in 60 3 cm Height 8 in 20 3 cm Weight 78 0 lbs 35 4 kg 90 0 lbs 40 8 kg Power Consumption 368 watts 552 watts Electrical Requirements 1...

Страница 8: ...8 incandescent lamps are required for each overhead fixture Lamps are sold in packages of sixteen 16 or as part of a specific lamp kit Examolite SD 840B 5000K Replacement Lamp Kit A LK ESD8450 This k...

Страница 9: ...not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of this material This manual as well as any revisions are the copyright o...

Страница 10: ...7 or 1 616 803 2705 Corporate Headquarters Europe Althardstrasse 70 8105 Regensdorf Switzerland Phone 41 44 842 24 00 Fax 41 44 842 22 22 Corporate Headquarters Asia Room 808 810 Kornhill Metro Tower...

Отзывы: