FOR XE 4/5/6

tent stakes

quantity

use

300 mm L

16 pcs.

walls

500 mm L

4 pcs.

outer tube

Dach

Reißverschluss-

abdeckung

Wand

4.4 WALL BALLASTS

The Wall Ballasts can be filled with water or sand/
gravel and can be connected to the wall using the 
attached toggles. 

FILLING WITH WATER

•   Open the velcro on the ballast cover and pull out the 

water bladder until the fill valve is visible.

•   There is a water bladder inside each ballast cover for 

filling with water. If filling the ballasts with sand or 
gravel, the water bladders must first be removed or 
they will become damaged.

•   Included in the Tube Ballast Set are a hose and 

various faucet adapters. Attach the hose to the 
faucet using the correct adapter.

•   Open the fill valve, insert the other end of the hose 

and fill the bladder with water.

•   Once full, remove the hose and close the valve and 

the velcro on the ballast cover.

•   Connect the four plastic toggles on the ballast to the 

large grommets on the wall. When doing so, make 
sure that the rubber-reinforced side of the Wall 
Ballast is facing down. For securing walls on XE 5 or 
XE 6 tents, the use of multiple wall ballasts on each 
wall is recommended.

water bladder

The following graphic shows which size/type tent stake should be used at which position.

wall

outer 

tube

roof

rain cover

wall

Содержание SE Series

Страница 1: ...USER MANUAL FOR XE SERIES TENTS Stand 19 M rz 2021 XE 4 XE 6 XE 5 Universal Wall XE 4 5 6 Standard Wall with Entrance Wall Option Wall Ballast XE 4 5 6 Tube Ballast Ballast Barrel ENGLISH...

Страница 2: ...ng your event tent for the fi rst time read this user manual carefully and follow the safety instructions All functions maintenance and repairs should only be carried out to the degree described in th...

Страница 3: ...ater Ballast Barrels 09 4 3 Tent stakes 10 4 4 Wall Ballasts 11 5 ELEMENTS 12 5 1 Walls 12 6 USE 12 6 1 General information 12 7 TAKEDOWN 14 7 1 Release Air 14 7 2 Fold 14 7 3 Pack 14 8 STORAGE 15 9 C...

Страница 4: ...rance height Total height Tube diameter Covered area Exterior side length Exterior side length 1 XE 4 XE 5 XE 6 Exterior side length 4 0 m 5 0 m 6 0 m Entrance height 2 0 m 2 5 m 3 0 m Total height 2...

Страница 5: ...or inflation deflation consists of a socket ring that is permanently welded to the bladder and a screw on valve housing with attached protective cover 3 2 1 INFLATE To inflate the tent the valve on th...

Страница 6: ...prevent the valve from functioning correctly 3 2 3 RAISING NOTE Raising the tent from the ground requires some assistance Before the tubes are fully inflated the middle of the tent must be actively li...

Страница 7: ...packed soil the X GLOO Anchoring Set tent stakes for the appropriate tent size can be used On snow or sand the Snow Anchors or Sand Anchors are to be respectively used in place of tent stakes On asph...

Страница 8: ...ons be sure to orient the tent against the wind so that it offers the least wind resistance Canopies in particular should not be aligned facing into the wind nor should open sides of the tent face int...

Страница 9: ...can be attached to each tube end Arrange the Tube Bal lasts next to each other and connect them to one an other using the plastic toggles Then attach the buckles on each ballast to the tube ends of t...

Страница 10: ...the tube ends by means of the included shackles You can at tach up to two Water Ballast Barrels directly to the rings on the tent base 4 2 3 EMPTYING To empty the barrels unscrew the cover on the bott...

Страница 11: ...rs must first be removed or they will become damaged Included in the Tube Ballast Set are a hose and various faucet adapters Attach the hose to the faucet using the correct adapter Open the fill valve...

Страница 12: ...or opening and closing The walls can also be attached inside out This makes it possible to have the printed side of a wall face either towards the inside or outside of the tent In windy conditions the...

Страница 13: ...countries Keep all valves free of sand and dirt and clean them when necessary in order to prevent faulty operation and pressure loss The tents can be damaged when sharp objects e g knives tools penet...

Страница 14: ...ay the air can escape almost completely without any effort 7 2 FOLD Turn the tent inside out so that the seam of the tube intersection loop is facing outwards Lay the tubes on top of one another with...

Страница 15: ...d If your tent is dirty first clean it while it is dry In order to avoid damage to the material coating the material should only be cleaned with warm water or a mild soapy solution if necessary and a...

Страница 16: ...igns are applied by digital printing to one side of a white material Due to the nature of the digital printing process the back side of the material remains white but printing on the opposite side may...

Страница 17: ...forming of water drops when the bladder is inflated If the damaged area can be seen from the outside and the size is less than 1 cm on the bladder then the bladder be sealed with the high performance...

Страница 18: ...t bladder through the lower tube opening g Carefully pull the replacement bladder completely into the tube making sure that a small amount protrudes from both ends of the tube h Ensure that the replac...

Отзывы: