background image

Copyright © 2021 WyreStorm Technologies | 

wyrestorm.com

EX-100-H2-EARC Quickstart Guide | 210524

UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973) 

[email protected]

2 of 4

Wiring and Connections

WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher.  Read through this section in it’s 
entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.

RS-232 Wiring

The EX-100-H2-EARC uses a 3-pin RS-232 with no hardware flow control.  
Most control systems and computers are DTE where pin 2 is RX, this can vary 
from device to device. Refer to the documentation for the connected device for 
pin functionally to ensure that the correct connections can be made.
Refer to  

RS-232 Mode Settings

 for details on setting RS-232 modes.

3rd Party Device

Pin 1 TX (Transmit) ---> To ---> RX (Receive)
Pin 2 RX (Receive)

---> To ---> TX (Transmit)

Pin 3 G (Ground)

---> To ---> G (Ground)

WyreStorm Connector

 

 IMPORTANT! Wiring Guidelines

 

•  The use of patch panels, wall plates, cable extenders, kinks in cables, and 

electrical or environmental interference will have an adverse effect on 
signal transmission which may limit performance.  Steps should be taken 
to minimize or remove these factors completely during installation for best 
results.

•  WyreStorm recommends the use of shielded category cable to minimize 

signal noise and interference.

•  WyreStorm recommends using pre-terminated HDMI cables due to the 

complexity of these connector types. Using pre-terminated cables will 
ensure that these connections are accurate and will not interfere with the 
performance of the product.

.

IR TX/RX Guidelines

 

•  Using WyreStorm infrared emitters and receivers is the best way to ensure 

that most IR coding formats are transmitted and received by the system. 
Other 3rd party emitters and receivers can be used; however, these devices 
must operate in the same manner as the WyreStorm devices.

•  Due to differences in IR across 3rd party control systems their IR ports 

should never be connected directly to a NetworkHD system as an 
incompatibility may exist. WyreStorm offers a cable that compensates for 
voltage differences as well adjusts for differences in the pins used within 
the port. Refer to the 

CAB-IR-LINK

 product page for more information.

IR TX Port Pinout

Connection for IR TX (transmit) uses a 3.5mm (1/8in) mono plug.

Tip:

Anode

Sleeve: Cathode (IR Signal)

IR RX Port Pinout

Connection for IR RX (receive) uses a 3.5mm (1/8in) stereo jack that outputs 
+5V DC to power the included IR receiver. 

Tip:
Ring:

IR Signal

+5V DC

Sleeve: Ground (GND)

Отзывы: