Quick Reference    

 

Clinotronic S      

 

 

Release 1.1.1 

 

WYLER AG

    

 

Tel.  +41 52 233  66 66  e-mail:

[email protected]

 

www.wylerag.com

 

Im Hölderli 13   

 

  

8405 Winterthur 

 

Outside Switzerland:

 contact our representatives

 

 

Switzerland 

 

 

www.wylerag.com/en/contact/representatives/

 

 

 

Thank you for choosing WYLER! 

Read this quick reference before start working with 

the Clinotronic S

Please observe the safety instructions. 

Brand and Type

 

Brand  

Clinotronic S,    

Types    

Art. 015-S-XG45 without  inserts

                                          

 

 

 

 

 

 

Art. 015-S-HG45 with 2 magnets each side 

Art. 015-S-PG45 with 2 threats M3 each side 

Warning!  

The following sign is used in this Quick Reference:  

This is intended to indicate special dangers 

Safety instructions 

The 

Clinotronic S

 complies with the applicable directives and standards, see: 

This Quick Reference - The nameplate on the back of the device 

The manual with the CE Declaration of Conformity Clinotronic S at  

www.wylerag.com

 

Intended Use 

 

The 

Clinotronic S

 is designed exclusively for measuring inclination angles. 

 

Attention!: There is no other use! 

Not intended use 

- The device does not serve as a support in vices! The precise housing can deform. 

- Do not immerse underwater! Since the device may suffer a short circuit inside. 

- Do not use as a hammer! The damaged measuring surfaces are then no more precise. 

- Do not throw the device! The housing can cause serious injury. 

- Do not use this device near sources of strong electromagnetic energy   Radiation (e.g.,   

  unshielded radio frequency source) because they can interfere with operation. 

- Only the original WYLER AKKUS may be used. 

- The batteries may only be charged with the included chargers. 

- The batteries may only be charged supervised. Do not leave the batteries lying around 

- The batteries must not be charged at temperatures below 0 ° C 

- The batteries must not be discharged at temperatures below -20 ° C. 

- Close the battery cap on the device carefully, but not by force! 

   For the tightness of the closure, an O-ring is mounted. 

- Observe the current regulations of the airlines regarding the 

   Transports of lithium-ion batteries in hand luggage and in checked baggage! 

- Do not immerse the device in water! Underwater, the built-in short-circuit 

   securing your effect!  

Technical datas, Mass, Weight, Protection, Operation, Storage 

Measuring Range: 

 45°   

 

 

Resolution: 

 

     5 arcsec oder 0.02mm/m 

Dimension L x H x D:   100 x 75 x 30 mm 

 

Weight:  

 

    400 g 

Protection: 

 

IP64   

 

 

Weight Scope of delivery:  850 g 

Storage: 

 

Im Koffer bei -20° bis +60° C  Operation temperature:     0° bis 40 ° 

 

Standard scope of delivery (accessories see www.wylerag.com)

 

 

1- 

Case

 for storage, transport and shipping for repair 

2- 

Clinotronic S,

  

 

3- 

Li-Ion Battery

  

4- 

Battery Charger

    

5- 

USB cable 

6- 

IR Zapper

    

 

7- 

wylerCONNECT MINI

, Bluetooth

 

   - 

Quick reference

 (Manual see: 

www.wylerag.com

)  

 

Decommissioning, disposal 

 

 When decommissioning the Clinotronic S,follow the local regulations for 

   Disposal of electronic waste. 

- The batteries must be removed from the device and both parts separately from  

   the be supplied for proper disposal.

 