MDC901-EVBHB Rev2021Jan5
MinDCet NV
Attention: Please refer to Evaluation Kit Important Notice on page 20
Page 16
Performance Evaluation
Electrical &Thermal Results
EVB performance was evaluated in a step-down conversion of 48 to 12 V application, sweeping over a
switching frequency range from 300 to 700 kHz and an output current (Iout) from 0.5 A to 30 A, with the
heatsink attached and fan turned on.
Efficiency
Peak efficiency is obtained at 500kHz, at 96.5%, keeping the output voltage constant at 12V.
Power Losses
The efficiency can be represented by the power loss value, which is key in defining the board operating
range and the necessity of installing the heatsink and fan assembly.