Analogue inputs S 1 - S 16

NOTICE

• Terminals 193/194 cannot be wired, they are empty.

Terminal

Sensor input

Sensor type

Assignment

161/162

S 1

TRK

Ts MT

163/164

S 2

DGF

MT T.hg

165/166

S 3

DGF

LT T.dsh

167/168

S 4

TRK

T.out

169/170

S 5

DGF

T.gc 1

171/172

S 6

DGF

T.gc 2

173/174

S 7

DGF

HR CO2 T.outlet

175/176

S 8

DGF

HR medium T.outlet

177/178

S 9

DGF

HR medium T.inlet

179/180

S 10

Not available

181/182

S 11

Not available

183/184

S 12

TRK

LT Ts

185/186

S 13

Not available

187/188

S 14

Not available

189/190

S 15

Not available

191/192

S 16

TRK

Control cabinet sen

-

sor

Содержание FRIGOLINK ANI-1F1-A

Страница 1: ...ation protection function Blocking time after compressor fault 3 step load shedding including Fastreturn Operating hours counter and cycle counter for each compressor Proactive oil return High pressur...

Страница 2: ...4 Functional earth FE 4 1 4 1 Input circuit diagram 5 Digital inputs DI 1 DI 20 5 Analogue inputs Uin 1 2 6 Analogue inputs Iin 1 Iin 5 6 Analogue inputs S 1 S 16 7 1 4 2 Output circuit diagram 8 Digi...

Страница 3: ...intended purpose WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when carrying out installation wiring or disassembly work Otherwise mains voltage and o...

Страница 4: ...1 4 Circuit diagram Fig 2 Circuit diagram Power supply Functional earth FE NOTICE To ensure failure free operation and reliable data communication connect the functional earth Connect the functional e...

Страница 5: ...7 N JHJUBM OQVUT 7_ Terminal Digital input Potential Assignment 101 DI 1 230V Not available 111 N 102 DI 2 230V Night signal 112 N 103 DI 3 230V Load shedding 1 113 N 104 DI 4 230V HR request 114 N 1...

Страница 6: ...230V HP rack fault 137 N 128 DI 18 230V GC fan fault 138 N 129 DI 19 230V Alarm input 1 NC 139 N 130 DI 20 230V Alarm input 2 NC 140 N Terminal Analogue input Potential Assignment 41 Uin 1 GND Not av...

Страница 7: ...t 161 162 S 1 TRK Ts MT 163 164 S 2 DGF MT T hg 165 166 S 3 DGF LT T dsh 167 168 S 4 TRK T out 169 170 S 5 DGF T gc 1 171 172 S 6 DGF T gc 2 173 174 S 7 DGF HR CO2 T outlet 175 176 S 8 DGF HR medium T...

Страница 8: ...1 202 NC 203 NO 204 Change over contact K 2 4 2 A 230V COM Alarm prio 2 205 NC 206 NO 207 NO contact K 3 3 1 A 230V COM MT CP 1 operation 208 NO 209 NO contact K 4 3 1 A 230V COM MT CP 2 operation 210...

Страница 9: ...ment Assignment 231 Semiconductor V 1 4 60VA 230V NO HG bypass 232 COM 233 Semiconductor V 2 4 60VA 230V NO Liquid injection 234 COM 235 Semiconductor V 3 4 60VA 230V NO Constant liquid injec tion 236...

Страница 10: ...4 3 Communication circuit diagram Fig 5 Communication circuit diagram Communication 7 7 7 N 3FMBZ 3FMBZ 4PMJE 4UBUF 3FMBZ 7 7 OBMPH 0VUQVU 6PVU 7 OBMPH OQVU 6JO N OBMPH OQVU JO JHJUBM OQVUT 7_ LQ P 9...

Страница 11: ...voltage is switched off Top hat rail installation 1 There are 2 fastening safety catches located on the back of the module A Press both fastening safety catches a downward until they engage with a cl...

Страница 12: ...red operating voltage green fault red 4 x LED green CAN bus data traffic CAN Tx CAN Rx Sensors 16 x DGF TRK C BUS communication 3 conductor CAN bus interface shielded galvanically isolated screw term...

Отзывы: