10. MAINTENANCE AND ASSISTANCE 

For better and longer duration of the product it should receive thorough general cleaning periodically. 

The instrument must be cleaned with a soft cloth moistened with water or neutral detergent, without using 

solvents or abrasive substances.   

If the instrument remains idle for a long period, remove the batteries from the terminal. 

During shipping, make sure not to subject the instrument to blows or excessive mechanical stress. 

In case of repairs or assistance, contact your dealer or an authorised service centre contacting 

[email protected] o[email protected]. 

 

11. CONFORMITY 

 
WUNDER MODEL BABY02 ELECTRONIC SCALE SERIAL N°......................................... 

We hereby certify that this instrument has been inspected and has successfully passed the functional test.   
It complies with the following standards and directives: 

EN 45501 / EN60601-1-2 / EN60601-1 

93/42/EEC 

 Medical Devices Directive 

 

12. IDENTIFICATION LABELS 

 

 

 

 

 

 

13. SCRAPPING AND WASTE DISPOSAL 

If set aside for a long period, protect those parts which could be damaged due to dust build-up 

Scrapping 

When you decide to no longer use this item, we recommend making it unusable. We also recommend 

making those parts which could be sources of danger harmless 

Waste disposal 

        EU 2002/96/EC 

This  product  complies  with  the  EU  Directive  2002/96/EC.  The  symbol  of  the  crossed-out  waste  bin  on  the 

appliance indicates that the product, needing to be treated separately from household waste, at the end of 

Содержание BABY02

Страница 1: ...sing the instrument 2 GENERAL RULES 2 3 SAFETY 3 4 SPECIFICATION 6 5 INDICATOR 6 6 INSTALLATION 7 7 ISTRUCTION FOR USE 8 8 PRINTER FUNCTIONS 11 9 ERROR MESSAGE 12 10 MAINTENANCE AND ASSISTANCE 13 11 CONFORMITY 13 12 IDENTIFICATION LABELS 13 13 SCRAPPING AND WASTE DISPOSAL 13 14 WARRANTY 14 15 INSTALLATION BABY HEIGHT ROD 15 16 INSTALL SECURITY BRACKETS 16 Manual_Baby02_V1 ...

Страница 2: ... simultaneously view Weight and weight difference calculation 2 GENERAL RULES Carefully read this manual before using the instrument as it supplies important indications concerning OPERATING SAFETY AND MAINTENANCE The descriptions and illustrations supplied in this manual are not binding WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being co...

Страница 3: ...ord does not create obstruction hazards Unplug the instrument before cleaning it Do not place the instrument in water or other liquids Perform maintenance and subsequent metric verifications regularly 3 1 Manufacturer s guide and declaration electromagnetic immunity Guide and Statement of manufacturer Electromagnetic emissions The electronic scales BABY 02 model is scheduled for operation in the e...

Страница 4: ... UT for 25 cycle 5 UT for 5 sec The power supply should be of the type used typically in commercial or hospital environments Note UT is the value of the voltage of the feed Power frequency Magnetic field IEC EN61000 4 8 3A m NOTE UT is the value of the power supply voltage CAUTION The medical device requires particular electromagnetic compatibility precautions and must be installed and used accord...

Страница 5: ... AM and FM and TV transmitters cannot be made theoretically and with precision To establish an electromagnetic environment due to fixed RF transmitters it should consider the electromagnetic survey of the site If the field strength measured at the place where you use the instrument exceeds the applicable level of compliance of the above it should be placed under observation normal operation of the...

Страница 6: ...apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 4 SPECIFICATION Model BABY 02 Capacity Max 3 6kg e 1 2g Max 6 15kg e 2 5g Max 10 20kg e 5 10g Approvazione OIML Class III Unit weight kg Display Double LCD 1 LCD 20mm weight with 5 active digits 2 LCD 12mm Dimensions 550 x 290 DISH Key functions ON ZERO OFF HOLD TARA PRIN...

Страница 7: ...Display Symbols Stable symbol To indicate that the weight is stable Minus weight Weight under zero Zero symbols Weight is at zero point Low battery Battery need to charge or replaced 6 INSTALLATION After removing the instruments from the packing check the integrity and right contents Put the scale far from source from of heat e vibration Put the scale on stable surface Indicator assembly is not as...

Страница 8: ...he TIME SETTING mode beginning with the top row with the flashing digit Press PRINT key after successful change to move to next step EX To input Dec 25 2016 00am Enter year Using TARE keys to decrease the value press HOLD key to move to next digit Press PRINT key after successful entry to move to next stage Enter date Using TARE keys to decrease the value press HOLD key to move to next digit Press...

Страница 9: ...hed accurately even they keep moving Once the HOLD key is pressed the weight reading will remain on the display after the item has been removed from the scale so the reading can easily be read Switch ON the scale using The diagnostic self checks is performed The scale is ready for weighing when the 0 0 kg displays on the screen Place the baby in the center of the tray gently Press When the triangl...

Страница 10: ...e remove the tare object from the tray and press key again Using memory function Milk difference This function allows automatically calculates the amount of Milk consumed After weighting the top row display will show the weight for example 3 000kg Press key to store the first weight the second display will show m1 And then press again to return to normal mode When the second weight be stored for e...

Страница 11: ... ASCII Serial RS232 Connecting with PC Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal New Connection Description Give new connection a name then click OK Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK Port Settings Click Bits per second to set up rate a...

Страница 12: ...clusive adaptor Locate adaptor plug on the rear side of indicator The battery should be recharged at least every 3 months regardless if it is used or not After a long period in storage e g over 3 months the battery should run a full cycle charge discharge to allow it to restore to full capacity 9 ERROR MESSAGE AC Jack connector ...

Страница 13: ...nder it 11 CONFORMITY WUNDER MODEL BABY02 ELECTRONIC SCALE SERIAL N We hereby certify that this instrument has been inspected and has successfully passed the functional test It complies with the following standards and directives EN 45501 EN60601 1 2 EN60601 1 93 42 EEC Medical Devices Directive 12 IDENTIFICATION LABELS 13 SCRAPPING AND WASTE DISPOSAL If set aside for a long period protect those p...

Страница 14: ...ries containing Lead Cd Cd batteries containing Cadmium Hg Hg Batteries containing Mercury ATTENTION Do not throw electric parts and used batteries away with household waste Dispose of the batteries by means of your closest collection centres 14 WARRANTY This certificate must be kept until the warranty has expired It must be presented together with the invoice tax receipt or delivery note providin...

Страница 15: ...e s home the customer must pay the fixed fee if however the appliance is repaired at an authorised Wunder Service Centre expenses and relative travel risk are borne by the user Wunder will not be held liable for damage of any nature caused directly or indirectly to persons animals or objects resulting from failure to comply with all the instructions indicated in this manual or anyway resulting fro...

Страница 16: ...MANUAL BABY02 WU150 REV 02 10 01 2017 16 16 INSTALL SECURITY BRACKETS FIG 1 1 LOOSEN THE PLATE AND REMOVE THE FEET fig 1 FIG 2 2 PLACE THE BAR AND SCREW THE ADJUSTABLE FEET fig 2 FIG 3 3 TURN THE SCALE AND MOUNT THE PLATE fig 3 ...