background image

1

Before you start:

Check the contents

Check the pump station contents against the list below. 

1.  Top pump connector and flow  

 

     temperature gauge.

2.  Circulating pump and washers.

3.  bottom pump connector and return          
     temperature gauge.

4.  ESBE Temperature control valve
  There are two versions available:

  VTA322 for 2-5 port manifolds up to 60

o

C

  VTA572 for 6-12 port manifolds up to 70

o

C

This guide is specific to our ESBE temperature control pump station and should be used in conjunction with the relevant Manifold user guide.

1.  Top pump connector and flow  
  temperature gauge.

2.  Circulating pump and 
washers.

3.  bottom connector with return 
temperature gauge. 

4.  ESBE temperature control valve.
*Small ESBE valve illustrated.

M11

ESBE Pump Station

✆ 

0800 083 2677

              

www.wundatrade.co.uk

THE BRAND YOU CAN TRUST

Revision date: 26-4-2018

In the unlikely event of any shortage please contact us and a replacement will be despatched immediately. Tel. 0800 083 2677

Содержание ESBE

Страница 1: ... to 70 o C This guide is specific to our ESBE temperature control pump station and should be used in conjunction with the relevant Manifold user guide 1 Top pump connector and flow temperature gauge 2 Circulating pump and washers 3 bottom connector with return temperature gauge 4 ESBE temperature control valve Small ESBE valve illustrated M11 ESBE Pump Station 0800 083 2677 www wundatrade co uk TH...

Страница 2: ...alves into the return bar Once the room to be heated reaches the required temperature the room thermostat sends a signal to switch the pump off and close the actuators if actuators are fitted This shuts off the water supply to the loops of pipe in the floor and therefore shuts off the heat supply Before assembly of manifold or pressure test familiarise yourself with the way the manifold works and ...

Страница 3: ...onnections at this stage Remove top and bottom pump holder adaptors from the pump holders Screw the pump holder adaptors into the left hand end Flow and Return bars tighten adaptors ensuring rubber O rings are in place and seated correctly against manifold bars forming a water tight seal 3 Assemble bottom pump holder by connecting the return temperature gauge ESBE mixing valve and pump connector M...

Страница 4: ...ould be set in accordance with the correct manifold user guide The manifold and pump set can now be filled with water and commissioned in accordance with our user guide video manifold pressure testing MO4 Ensure the pump is filled and vented set floor heating to call for heat and then select desired pump setting in accordance with pump user guide A good practice is to fit isolation valves when ins...

Страница 5: ...an a domestic central heating system The Code recognises that it is not possible to clean a system without the application of a cleanser Different products may be used depending on the nature of the system involved The most effective corrosion inhibitors act by reacting with the surface of the metal to produce a protective film in the form of a stable complex The effectiveness of a given corrosion...

Страница 6: ...6 Your Notes Tech support opening hours are subject to change please visit our website for the latest information Revision date 26 4 2018 ...