WST FBM200A Скачать руководство пользователя страница 1

 
 

 

 

 
 
 

Beacon Monitor 

Operator’s Manual 

 
 
 

 
 

for model: 

 

FBM200A 

 
 
 
 

Version 2.00

 

 

Содержание FBM200A

Страница 1: ...Beacon Monitor Operator s Manual for model FBM200A Version 2 00...

Страница 2: ...ents trademarks copyrights or other intellectual property The purchaser shall not in any event be entitled to and WST shall not be liable for indirect special incidental or consequential damages of an...

Страница 3: ...n Decode area 7 Full Screen button 7 Deleting records 7 QR Code 7 Map Mode 8 Map Selections 8 Selected Log Items Only 8 Location Beacons 8 Non Location Beacons 9 Normal Mode Self Test Test Protocol 9...

Страница 4: ...onditions 20 SMS Configuration 20 Customized Notifications 21 Help About Beacon Monitor 22 Help Contents Updates 23 Help Contents Frequently Asked Questions 23 Help Contents Feedback 24 RECEIVING BURS...

Страница 5: ...box on the right Be sure to keep the accessories box for handy storage of the Beacon Monitor Operator s Manual and accessories when not in use Please verify the contents of your package It should con...

Страница 6: ...ACON MONITOR Please read this Operator s Manual to become familiar with the operation of the Beacon Monitor Relay contacts button Reset button LED Indicator Antenna USB Interface Mounting Flange 4 but...

Страница 7: ...1 25 to 2 50 in diameter Connect the Antenna Extension cable between the antenna and the RF IN connector on the Beacon Monitor Installing the Application The Beacon Monitor application must be install...

Страница 8: ...een will appear Click Next If Java TM is not installed on your computer you will be prompted to install it Follow all on screen instructions Once completed click Finish The Beacon Monitor icon will ap...

Страница 9: ...both the power supply and the communication link to the receiver When the FBM200 receiver is located the Connection Status in the Status section will show Connected The LED Indicator on the top of th...

Страница 10: ...eacons and the receiver The Setup button will switch the screen to the Setup mode This mode allows the user to setup the application and receiver as needed The Status section displays the status of th...

Страница 11: ...ze the Beacon Monitor screen click the Full Screen button To un maximize the screen press it again To delete records select a record and right click the mouse then click Delete record To delete multip...

Страница 12: ...map Selected Log Items Only Check the box when you want only the items selected in the Log Area Monitor Mode to be viewed on the map Location Beacons The user can check this box to show all location p...

Страница 13: ...mapping applications The Map Area will show the Receiver icon and all of the received beacon bursts as selected by the user Icons If the decoded beacon includes location data the beacon icon will be...

Страница 14: ...ck on the Receiver icon to zoom in automatically Pan Left click and drag left right up or down or use the keyboard arrow keys Rotate or Tilt Right click and drag left or right to rotate Right click an...

Страница 15: ...o the Setup mode The setup menu has a selection of items See details of each section in the Setup Items section below The Setup panel is the information or setup area for each item in the Setup menu S...

Страница 16: ...or the connected receiver maximum 8 characters The latitude and longitude of the receiver must be entered for the receiver to show on the map Use decimal degrees format Click Apply to save any changes...

Страница 17: ...word 4 to 12 characters Then re type the password and click Apply Passwords Login Enter your password and click OK to login Logout If the Beacon Monitor program is password protected a Login Logout bu...

Страница 18: ...hen a Normal Mode Live Burst is detected so that the user can take action and notify the authorities of a potential false alert Check or un check the boxes on the Receiver Alarms and Computer Alarms s...

Страница 19: ...tion method based on the mode of the received beacon burst Check or un check the boxes on the Receiver Alarms setup page to suit your requirements These alarms are reset by clicking the Alarm Reset bu...

Страница 20: ...ty to the lowest level of 55 dBm The default sensitivity level is 115 dBm The Beacon Monitor has sophisticated algorithms for preventing false triggering However burst reception may be hindered when o...

Страница 21: ...beacon burst It is advised to always be alerted when a Normal Mode Live Burst is detected so that the user can take action or notify the authorities of a potential false alert There are two alarm not...

Страница 22: ...d through the computer audio system Resetting Alarms To clear the alarms click on the Alarm Reset button Alarm Reset button NOTICE All Normal Mode bursts have the potential of being received by the sa...

Страница 23: ...r the SMTP Mail server information for your outgoing mail server Contact your network administrator for this information Enter your email address This will be the senders email If your outgoing mail s...

Страница 24: ...k the boxes to suit your requirements so that the SMS notifications are sent for the corresponding beacon mode SMS Configuration Enter the SMTP Mail server information for your outgoing mail server Co...

Страница 25: ...s in the Add Message box Click Apply to save the changes Click Test to send a SMS message NOTE You are responsible for any charges incurred relating to SMS messages Customizing the email and SMS notif...

Страница 26: ...n Monitor screen shows the Beacon Monitor Software Revision and Receiver Information including Receiver Model Receiver Serial Number Receiver Firmware Version and internal Receiver Temperature Help Ab...

Страница 27: ...complete the update You can also manually check for software updates by clicking on the Check for Updates buttons If an update is available a pop up notice will advise you This page will show a list o...

Страница 28: ...elp us to continually improve our product please send us your feedback If you wish to receive a response please include your name and email address All information received is kept confidential Help C...

Страница 29: ...5 Hex ID will be shown in red see Index item 2 below Visual Alarm Normal Mode Live Burst reception NOTICE All Normal Mode bursts have the potential of being received by the satellites causing a false...

Страница 30: ...information for each burst Date Self Test Flag Default Hex ID 30 Hex Power dBm Frequency Country Identifier Position Flag Latitude Longitude Beacon Type Test Protocol Flag Decode Full details Receive...

Страница 31: ...SMS messaging notifications Q Why does Java need to be installed on my machine A The Beacon Monitor application is written in Java programming language The application will not function unless Java i...

Страница 32: ...sv file located in Program Files WS Technologies Inc Beacon Monitor Log Q Where is the best location to place my receiver A You should place the receiver as far away as possible from away from sources...

Страница 33: ...nge 55 C to 85 C Dimensions 108 x 63 x 26 mm 4 3 x 2 5 x 1 0 inches Weight 0 230 kg 0 5 lbs INCLUDED USB Cable 3 m length AC to USB Adapter Ethernet cable 3 m length Molded 406 MHz Monopole Antenna Ou...

Страница 34: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Страница 35: ...8 EN 61000 4 4 2004 EN 61000 4 5 2005 EN 61000 4 6 2008 EN 61000 4 11 2004 Following the provisions of the normative European Council Directive 2004 108 EC EMC Directive Product conformance to cited p...

Страница 36: ...r the performance thereof and does not make any warranty to the purchaser s customers or agents CALIBRATION The Calibration of the FBM200 Beacon Monitor is optional If required the calibration date ap...

Страница 37: ...91 80 28371857 Indonesia indonesia_mcc yahoo com 62 21 5501449 62 21 5501513 Italy itmcc247 cospas sarsat italy it 39 080 5341571 39 080 5342145 Japan jamcc kaiho mlit go jp 81 3 35916106 81 3 3591610...

Страница 38: ...er Port _________________ SMTP Username _________________ SMTP Password _________________ SMS data SMS Mail Server _________________ SMS Mail Sever Port _________________ SMTP Username _______________...

Страница 39: ...35 Notes...

Страница 40: ...36 Notes...

Отзывы: