Pre-Installation Information
When installing the
Willoughby Stainless Fountains' WOPF-1 Series
fountain system:
Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location�
The valve assembly, including the spray head,
MUST NOT BE
connected until
after
all lines have
been flushed to remove the small particles of debris that are inherent with new construction projects
and all chemicals that are used in flushing are purged from the system.
Chemicals used in flushing plumbing systems can attack the internal components of the valve and
spray head and severely damage them, so any flushing of the system must be followed by a full
flushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if
allowed to enter the valve assembly and spray head can cause poor performance or outright failure�
Again
DO NOT
attempt to connect the valve assembly and spray head until
after
all flushing is
complete and pure water is the only media that will be passing through the system� Damage to the
valve assembly or spray head caused by harsh chemicals or debris will not be covered by the
manufacturer's warranty�
Any fittings provided by the installer should be made of plastic to electrically isolate the unit from the
building or connected plumbing system�
The grounding of electric equipment such as telephones, computers, etc, to water lines is a common
procedure. This grounding can cause electrical feedback into a water fountain or similar fixture,
causing electrolysis, which results in a metallic taste or an increase in the metal content of the water�
This can easily be avoided by using the proper materials as indicated�
INSTALLATION INSTRUCTIONS
Visit our website at http.//www.willoughby-ind.com
2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221
(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065
© Rev. 11/2007
Page 3
Installation notice!
Check Rough-in location and flush lines prior to hook up!
When installing the
Willoughby Industries’
WAW, WAF, or WWF series
washfountains or lavatory deck systems:
Before Step 1 of the installation instructions, ensure that rough-ins are in the correct
location.
It is essential that the water supply lines be thoroughly flushed prior to making final
connection to the hot and cold water supply lines. These lines
must
be flushed
sufficiently to remove the small particles of debris that are inherent with new
construction projects. If this debris is not removed, the valving in these units
will be
damaged
. Do not attempt to remove aerators to flush debris into the lavatory. The
damage can only be fixed by replacing the valves. Damage to valves caused by debris
will not be covered by the manufacturers warranty.
Installation notice!
Check Rough-in location and flush lines prior to hook up!
© Rev. 5/2010
Check Rough-In location
PRIOR
to installation
Flush lines thoroughly
PRIOR
to hook-up
INSTALLATION INSTRUCTIONS
Visit our website at http.//www.willoughby-ind.com
2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221
(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065
© Rev. 11/2007
Page 3
Installation notice!
Check Rough-in location and flush lines prior to hook up!
When installing the
Willoughby Industries’
WAW, WAF, or WWF series
washfountains or lavatory deck systems:
Before Step 1 of the installation instructions, ensure that rough-ins are in the correct
location.
It is essential that the water supply lines be thoroughly flushed prior to making final
connection to the hot and cold water supply lines. These lines
must
be flushed
sufficiently to remove the small particles of debris that are inherent with new
construction projects. If this debris is not removed, the valving in these units
will be
damaged
. Do not attempt to remove aerators to flush debris into the lavatory. The
damage can only be fixed by replacing the valves. Damage to valves caused by debris
will not be covered by the manufacturers warranty.
Installation notice!
Check Rough-in location and flush lines prior to hook up!
© Rev. 5/2010
Check Rough-In location
PRIOR
to installation
Flush lines thoroughly
PRIOR
to hook-up
Pre-Installation Information