background image

 
 
 
 
 
 
 
 

 

 
 
 
 

 

DRS Digital Recording Solution Series 

Installation and Maintenance Guide 

v 1.1 

Содержание DRS5004

Страница 1: ...DRS Digital Recording Solution Series Installation and Maintenance Guide v 1 1...

Страница 2: ...with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user wil...

Страница 3: ...after installation 4 If DRS does not operate properly please contact your Wren reseller for after sales service Tampering or disassembling the product will void the warranty 5 Security surveillance la...

Страница 4: ...udio 19 4 4 Supplying Power 20 5 Running OSD Menu 22 5 1 Using Menu 22 5 2 Dialogue Box to Edit a Word 23 6 Setting Remote Controller 24 6 1 Setting ID of DRS Digital Recording Solution 24 6 2 Selecti...

Страница 5: ...cording 32 8 3 7 Apply 32 9 Connecting and Configuring DIO Ports 33 9 1 Connecting and Configuring Sensor 34 9 1 1 Specification 34 9 1 2 Connecting Sensor Input 34 9 1 3 Configuring Sensor at OSD Men...

Страница 6: ...394 Port 48 10 2 Connecting IEEE1394 Device 48 11 Network Monitoring Managing 49 11 1 Connecting Ethernet 49 11 2 Configuring DRS Network Information 50 12 Using DVR Manager 51 12 1 PC System Requirem...

Страница 7: ...14 7 3 Using Load Preset 65 14 7 4 Using Save Preset 65 14 8 Using Relay 65 14 9 Using Screen Lock 66 14 10 Using Monitor B DRS5116 Model Only 67 14 10 1 Monitoring 67 14 10 2 Multi Channels Playback...

Страница 8: ...85 16 4 2 Setting Motion Detection 86 16 4 3 Text 87 16 4 4 Setting Global Alarm Recording 88 16 4 5 Setting by Channel 90 16 5 Alarm Act 91 16 5 1 Schedule 91 16 5 2 Setup 92 16 6 Monitor 93 16 7 Mo...

Страница 9: ...e 107 17 1 Using Text Device 107 17 1 1 Setting at Text Menu 107 17 1 2 Setting at Serial Setup s RS232 Menu 108 17 1 3 Setting at Alarm Rec Menu 109 17 1 4 Setting at Normal Rec menu 109 17 2 Using K...

Страница 10: ...0ips Max 60fps Max 120fps Max 240fps NTSC PAL Realtime Monitoring 30 25 30 25 30 25 30 25 Built in software multiplexer Y Y Y Y 1 4 9 13 16 Ch Mode on Monitor PC Y Y Y Y 4TB Storage Capacity IEEE 1394...

Страница 11: ...t Unpack and check all the items shown below 1 1EA DRS Unit DRS5116 model shown 2 AC DC Power Cord 1EA DRS5004 5008 require DC adaptor 3 CD ROM Including DVR manager 1EA 4 Remote Controller 1EA 5 Guid...

Страница 12: ...verview DRS5116 Wren 2003 09 06 v 1 0 12 3 Description Function DRS5116 Front 1 Power switch 2 Function buttons 3 LED 4 I O Port cover 5 USB connector 6 IEEE1394 connector 7 Remote controller receiver...

Страница 13: ...or for video output 11 BNC connector for monitor A output 12 BNC connector for monitor B output 13 Terminal block for sensor relay and serial input output 14 IEEE1394 connecter 15 Terminal block for R...

Страница 14: ...Overview DRS5116 Wren 2003 09 06 v 1 0 14 DRS5004 Front Panel 1 LED 2 IEEE1394 connecter 3 Remote controller receiver 4 USB connecter 5 Function buttons 6 Bracket fixing hole for rack mount...

Страница 15: ...Audio input output connector 11 RS232 connecter 9Pin D Sub 12 Terminal block for RS232 422 485 13 Terminal block for Sensor input 14 Terminal block for relay output 15 Video output for Monitor or VCR...

Страница 16: ...Overview DRS5116 Wren 2003 09 06 v 1 0 16 DRS5008 Front Panel 1 LED 2 IEEE1394 connecter 3 Remote controller receiver 4 USB connecter 5 Function buttons 6 Bracket fixing hole for rack mount...

Страница 17: ...Audio input output connector 11 RS232 connecter 9Pin D Sub 12 Terminal block for RS232 422 485 13 Terminal block for Sensor input 14 Terminal block for Relay output 15 Video output for Monitor or VCR...

Страница 18: ...or PAL 2 The DRS sets video signal s impedance 75 automatically Impedance is set as 75 When connecting a device to video output impedance will be Hi z status 3 Video type NTSC PAL should be changed pr...

Страница 19: ...V monitor to the DRS Unit with the BNC cable as shown below Note The DRS5116 has two monitor output ports for A Normal and B Spot When connecting only one monitor use monitor A DRS5004 5008 5016 have...

Страница 20: ...it DRS5004 DRS5008 DRS5016 DRS5116 12VDC supplied 12VDC supplied 110 220VAC 110 220VAC DRS5016 DRS5116 5000 Series Note 1 When supplying power the DRS starts booting automatically 2 When pressing the...

Страница 21: ...Installation and Connection DRS5116 Wren 2003 09 06 v 1 0 21 DRS5004 DRS5008 1 Connect the power cable 2 Turn on the power switch located on the DRS rear panel...

Страница 22: ...ub menu Use the arrow buttons to move within the sub menu list To move to the setting page press the ENTER button To exit the setting page press the EXIT button 3 Setting Page The selected item is sho...

Страница 23: ...For example in order to select C press the 3 and 2 buttons 2 Using the arrow button select a value using the or buttons The intersection of the horizontal and vertical bar is a selected value Press t...

Страница 24: ...on and press the ENETR or buttons 3 Select Miscellaneous from the sub menu list using the button and press the ENETR button 4 Select Remote Control ID and press the ENETR button 5 Select a value using...

Страница 25: ...zer sounds during the first two seconds Note Because the remote controller ID is sixteen the DVR will correspond until the ID button is pressed sixteen times 6 3 Operable Range of Remote Controller 6...

Страница 26: ...Installation and Connection DRS5116 Wren 2003 09 06 v 1 0 26 7 DRS Configuration 7 1 Basic Configuration Camera Sensor Rely Monitor Quantities are Model Dependant 7 2 Advanced Configuration...

Страница 27: ...Installation and Connection DRS5116 Wren 2003 09 06 v 1 0 27 7 3 External Storage Backup Configuration 7 4 Internet Intranet Configuration...

Страница 28: ...ing Image After the initial start up images are displayed in a multi split screen according to the connected channels and specific model being installed The following example is when four channels are...

Страница 29: ...he buttons and press the EXIT button when finished 8 2 2 Daylight Saving 1 Daylight Saving Time is only activated for time zones that use Daylight Savings If activated press the ENTER button to enter...

Страница 30: ...8 2 6 Time 1 Select Time using the or the buttons and press the ENTER button 2 Select HH MM using the buttons and select the value using the buttons 3 Press the EXIT button when finished 8 2 7 Apply...

Страница 31: ...tup 2 Move to sub menu by pressing the ENTER or the buttons 3 Select Recording using the buttons and press the ENTER button 8 3 1 Configuration Status This function displays the recording configuratio...

Страница 32: ...defined by User 8 3 4 Speed fps When Recording Speed Quality is set as Custom values can be set manually 1 Select Speed using the buttons and press the ENTER button 2 Select a value using the buttons...

Страница 33: ...block follow the instructions below Note the different types of wire that can be used Stranded Wire Peel off the wiring cover 8 10mm and solder it The wire gage should be AWG 22 26 Solid Wire Peel off...

Страница 34: ...Normal Close N O Normal Open type Supported sensor Dry contact Spec Connecting Connecting the trimmed wire to terminal block Available input pulse range Min 500ms Performance Output current Typical D...

Страница 35: ...9 1 3 1 Global The Global is used for setting 16 sensors simultaneously to one of three types Off Normal Open NO Normal Close NC 1 Select Global and set a type 2 Press the Apply button in order to con...

Страница 36: ...menu 2 Select the sensor number S1 S2 etc and press the Enter button to configure Use the buttons to select On or Off Press the EXIT button when finished 3 When activated the Pre Post Alarm function...

Страница 37: ...When activated the Pre Post Alarm function will cause the HVR 08E to record images at the specified speed and quality for a length of time before and or after the sensor is triggered Note 1 This menu...

Страница 38: ...ll models normally the following conditions are required Output Ch 4Ch Relay differential outputs Output type Dry Contact Spec Connecting type Connect the trimmed wire to the screwless terminal block...

Страница 39: ...a sensor input or with motion detection for each of the four time schedules Weekday Day Weekday Night Weekend Day Weekend Night Relays can also be controlled locally by pressing the SEARCH RELAY butt...

Страница 40: ...r Pan Tilt Zoom The DRS series units have most major PTZ protocols already pre programmed Certain makes and models not supported can still be controlled using the Transparent Protocol For a list of su...

Страница 41: ...Installation and Connection DRS5116 Wren 2003 09 06 v 1 0 41 9 3 2 Diagrams of Serial Ports 9 3 2 1 Diagram of COM1 9 3 2 2 Diagram of COM2...

Страница 42: ...Installation and Connection DRS5116 Wren 2003 09 06 v 1 0 42 9 3 2 3 Diagram of COM3 9 3 2 4 Diagram of COM4 9 3 3 View of COM3 COM4 Serial Ports...

Страница 43: ...OSD Menu Configure PTZ COM ports and available modes at System Serial Setup After completing serial setup configure the base address and port for each channel under the Camera menu tab When connecting...

Страница 44: ...ough the COM1 RS232 serial port Connect to COM1 RS232 9pin D Sub of the DRS5116 and configure the Serial Setup sub menu under the System tab and Text sub menu under the Alarm Source tab 9 4 2 Configur...

Страница 45: ...v 1 0 45 9 4 3 Configuring Text 1 Select the Alarm Source menu among OSD menus 2 Select the Text and set each value Note Before installing any external device consult with the local distributor Some...

Страница 46: ...do not exceed the rated values of the USB device USB Spec Ver 1 1 Max 12M bps Available Device USB Memory Stick Output Voltage Current Max 200mA per DC 5V Port Note The disk should be formatted with F...

Страница 47: ...Output Video outputs are available on the DRS5016 5116 models only DVR s video in output is composed of loop through BNC connectors in an analog format The DVR recognizes the connection status and au...

Страница 48: ...nsult the local distributor 10 2 Connecting IEEE1394 Device When using FireWire supported by external HDD hard drive bays can be connected to one port in the front panel or one port in the rear panel...

Страница 49: ...te site via Internet Intranet 11 1 Connecting Ethernet 1 Turn off the DRS power switch 2 Connect the DRS to hub with Ethernet cable 3 Turn on the DRS power switch Note 1 Supply power to the DRS after...

Страница 50: ...uttons and press the ENTER button 4 Select IP Addr using the buttons and press the ENTER button 5 Press the EXIT button after entering the IP address in the dialogue box 6 Select Net Mask using the bu...

Страница 51: ...above VGA 16 MB or above 32 MB or above OS Windows 2000 XP Windows 2000 XP Resolution 1024 X 768 pixels or above 1024 X 768 pixels or above Network 100 Base TX Fast Ethernet 100 Base TX Fast Ethernet...

Страница 52: ...hich components to install and press the Next button 5 Browse and choose a directory if the default directory is not preferred Click the Install button after selecting a directory to install 6 Click t...

Страница 53: ...2 3 Uninstalling DVR manager 1 Click Windows Start Button 2 Select and click the Uninstall icon to run the Uninstall Shield 3 The DVR Manager program will be automatically deleted 12 4 Configstation C...

Страница 54: ...ation and Connection DRS5116 Wren 2003 09 06 v 1 0 54 12 5 Monitor Click the related icon and run the DVR Manager Monitor program 12 6 Playback Click the related icon and run the DVR Manager Playback...

Страница 55: ...i e When blinking rapidly HVR 16E is recording at a high rate when blinking slowly the HVR 16E is recording at a lower rate PLAY Displays playback status The rate of blinking indicates the speed of p...

Страница 56: ...d USB 13 2 Rear Panel DRS5016 5116 Models 1 Audio In Output 1 audio input 1 output 2 Ehternet 3 Power Connector 4 Video Input Loopback 16 video inputs loopback port 5 Video Output 2 video outputs Moni...

Страница 57: ...data is being transmitted or received over the Ethernet REC Displays the image recording status The rate of blinking indicates the speed of recording i e When blinking rapidly HVR 08E is recording at...

Страница 58: ...e or to toggle the Relay On Off function in the Monitoring mode 9 Direction Replaying Button MENU To set PTZ and access Configuration menu ENTER To enter and confirm the selected menu HELP To change t...

Страница 59: ...tion When blinking data being transmitted or received over the Ethernet REC Displays image recording status The rate of blinking indicates the speed of recording i e When blinking rapidly HVR 04E is r...

Страница 60: ...lly display all connected channels in successive order MULTI To select the multi channel display 4 9 16 13 divided screen SELECT To select video channel for PTZ control ZOOM To activate the digital zo...

Страница 61: ...nfiguration menu 13 6 Rear Panel DRS5004 Models 1 Serial Port DIO Serial RS232 9Pin D Sub Connector RS232 422 485 terminal block Sensor In 4 sensor inputs Relay Out 4 Alarm Relay outputs 2 Audio port...

Страница 62: ...ll outlet and apply power to the unit The LED will come on and the DRS will start booting After start up the basic screen quad split is displayed If user password is set a dialogue box for entering th...

Страница 63: ...and press the ENTER button Set any value between 1 and 60 seconds In order to move to the sequence mode from any viewer mode press the SEQ button Note The sequence mode can run only when connected and...

Страница 64: ...box can be moved each 10th step to the left and right and 7th step up and down To move the zoom box use the Arrow button To cancel the zoom box press the ZOOM button once more 14 7 Viewing with Conne...

Страница 65: ...preset on the front panel 14 7 4 Using Save Preset To set a new preset point for dome camera during live monitoring mode Move dome camera to the desired position using the Pan Tilt and Zoom Focus menu...

Страница 66: ...to operate properly the user password should be set While pressing the EXIT LOCK button for 2 3 seconds the Lock mode will run with a Screen Locked message on the screen When the User Password is set...

Страница 67: ...ously 13 split screen mode User sequence When monitoring 12 channels by 13 split screen mode in Monitor A administrator monitors four channels by user sequence mode in Monitor B simultaneously Quad sp...

Страница 68: ...ayback of the last 30 seconds of recorded video at 1X speed Note When pressing the play button in the multi monitoring mode channel 1 is always the channel displayed More specifically images recorded...

Страница 69: ...n playback mode and replay at 1x speed After pressing PAUSE PLAY will advance recorded images frame by frame STOP To stop replaying PAUSE To pause replaying FFW Each press of the button will increase...

Страница 70: ...owser Press the ENTER button after entering the desired Date Time or select from the Event Log browser The selected images will begin to playback To exit from search mode press the EXIT button Note Us...

Страница 71: ...the recorded data This menu is activated duringthe playback mode Press the SELECT button and the MENU button in the playback mode 15 3 1 Copy Data The Copy Data function is used to copy a specific dat...

Страница 72: ...he Backup Manager does not support USB devices The Backup Manager will ONLY work with devices connected through IEEE1394 FireWire ports 15 3 3 Delete Data The Delect File is used to delete a specific...

Страница 73: ...me of factory installation the time zone will be set as UTC 00 00 Dublin Set the time to the local time zone Changing the DRS Digital Recording Solution time may cause time conflict with the recorded...

Страница 74: ...ylight Saving The Daylight Savings option is linked to the time zone Daylight Savings is only activated for time zones that use Daylight Savings For example selecting GMT 7 00 Arizona will disable the...

Страница 75: ...ur to Minute use the left right arrow buttons To select each month each day etc use the up down arrow buttons Apply Date Time Press the Apply Date Time button to confirm the above settings A window wi...

Страница 76: ...with the Normal and Alarm recording Custom Setup will be displayed Note When all analog cameras normal recording conditions are set identically the status is marked as Macro Setup Otherwise it is mar...

Страница 77: ...tton confirms the Quick Setup Recording settings The DRS will begin recording after pressing the Apply button and exiting from the recording menu 16 2 Camera This menu is used for configuring individu...

Страница 78: ...6 v 1 0 78 DRS5004 Model OSD Menu Button control Press the MENU button and use the ARROW keys to move to each channel below the Camera tab Name Assign a customized name to the channel Press the ENTER...

Страница 79: ...DRS5116 front panel When using the ARROW buttons use the PLAY button to select each choice The intersection between the horizontal and the vertical bar is the selected choice Press the button to conf...

Страница 80: ...ightness Contrast Set the value between 9 and 9 using the buttons Covert If setting Covert as On the channel will be hidden in the monitoring mode After pressing the ENTER button set On Off using the...

Страница 81: ...ed by the Normal Recording settings 16 3 1 Setting Global DRS5016 5116 Models Only This screen is used for setting all channels to the same conditions DRS5016 5116 OSD Menu Note 1 Different from Quick...

Страница 82: ...003 09 06 v 1 0 82 16 3 2 Setting by Channel Time Schedule Each camera can be set to record based on four time schedules 1 Weekday Day 2 Weekday Night 3 Weekend Day 4 Weekend Night Each schedule can b...

Страница 83: ...ween Monday and Sunday using the buttons Weekend is set automatically based on the Weekday range Day Start End Set the range for Day using the up down buttons The Night range is set automatically base...

Страница 84: ...w Standard High Custom same as above Setting Special Time To set Special Time move to System tab Up to four zones can be designated as Special Time Event Recording Press the ENTER button to access the...

Страница 85: ...under the Normal Recording tab to On 2 The Alarm Source should be set before the alarm recording menu 16 4 1 Setting Sensor It is used for settingthe sensor type The DRS supports Normal Open N O and...

Страница 86: ...is possible to set each channel separately Motion Detection Choose from among four sensitivity conditions Off Low Standard and High MD Area Customize the MD area among 64 sectors 8 sectors x 8 sectors...

Страница 87: ...omize the motion detection area The area is divided into 64 blocks 8 x 8 The selected MD area is indicated in dark gray To remove blocks from motion detection select the block using the ARROW buttons...

Страница 88: ...lways inserted So when this header data is transmitted the DRS can recognize it as the starting point A maximum of two headers can be set Delimiter Because the delimiter value may be different refer t...

Страница 89: ...work of sensor MD Pairing means thechannel runs sensor MD by 1 to 1 Text In order to display or record text with an image it should be set as On Note 1 After setting it as Global press the Apply butt...

Страница 90: ...sition according to the alarm input Recording Speed Quality There are four conditions Low Standard High Custom All conditions except Custom synchronize Speed fps and Quality automatically Low setting...

Страница 91: ...and E mail should be also configured 16 5 1 Schedule Select Action Source In the menus of Relay1 Relay4 Buzzer and E mail Sensor or MD can be set upto 4EA or ANY And Text can be set as On Off For sel...

Страница 92: ...zer when an alarm MD or sensor is triggered E mail Notification DRS5116 Model Only The E mail Notification allows user to enter E mail address to receive alarm information SMTP The SMTP enters the DNS...

Страница 93: ...Keep the pop up screen keeps holding In order to cancel the keep mode press another channel button Seq Switching sec This function is used to set sequence time between 1 and 60 seconds Note If channe...

Страница 94: ...Keep the pop up screen keeps holding In order to cancel the keep mode press another channel button Seq Switching sec This function is used to set sequence time between 1 and 60 seconds Note If channe...

Страница 95: ...them Recording Set to On using the ENTER button and the ARROW buttons to record audio Audio Gain This function increases or decreases the sensitivity to the audio signal It can be set between 7 and 8...

Страница 96: ...ay Night Weekday Start End Press the ENTER button to access the Time Setting Set the range for Weekday between Monday and Sunday using the buttons The Weekend is set automatically based on the Weekday...

Страница 97: ...Basic Configuration DRS5116 Wren 2003 09 06 v 1 0 97 16 8 3 Special Time Up to four zones can be designated as Special Time...

Страница 98: ...Admin Password Designate an Administrator s Password to control access to the Configuration menu and full system control authority The default password is 9999 Remote Setup When the remote setup is se...

Страница 99: ...based on a first in first out basis Images recorded based on Alarm conditions are not written over Auto Del Alarm If enabled all images Normal and Alarm will be written over based on a first in first...

Страница 100: ...Ethernet If the DRS is connected on xDSL line that needs PPPoE process to connect to the Internet the administrator should select xDSL However if the xDSL line does not need PPPoE process the adminis...

Страница 101: ...rnet IP Address NetMask and Gateway Address DNS The administrator may configure IP address subnet mask gateway address and DNS addresses of the DRS 16 8 6 2 xDSL If the DRS is connected on xDSL line a...

Страница 102: ...an open port some firewalls and or ISPs block certain ports press the ENTER button and use the dialogue box TP Server Port This port is used for Transparent Protocol server Firewall Port If there is a...

Страница 103: ...Mode Set the DRS5116 s NTP mode between Client and Server NTP Server Loc The NTP Server Loc is possible to set after setting the NTP Mode as Client Set whether the NTP server is on the Local Network o...

Страница 104: ...f 4 COM ports Device Designate the connected external device Interface The interface is used to designate the protocol on the RS422 RS485 menu COM1 and COM3 are fixed as RS232 Baud rate Parity Stop bi...

Страница 105: ...controller Aim the remote controller at the DRS5116 Press the ID button of the remote controller until the DRS reacts If the remote controller s ID agrees with the DRS all the LEDs on the front panel...

Страница 106: ...e the first DRS has five cameras and the second DRS has six cameras the keyboard PTA address of the fisrt DRS should be set as 1 and the second DRS be set as 6 Be cautious that the PTZ addresses are a...

Страница 107: ...er to use the text device the following four menus should be set Text menu Serial Setup s RS232 menu Alarm Rec menu and Normal Rec menu 17 1 1 Setting at Text Menu Set both recording and monitoring as...

Страница 108: ...Advance Configuration DRS5116 Wren 2003 09 06 v 1 0 108 17 1 2 Setting at Serial Setup s RS232 Menu Set RS232 s device menu as Text Then set the baud rate parity stop and data...

Страница 109: ...Advance Configuration DRS5116 Wren 2003 09 06 v 1 0 109 17 1 3 Setting at Alarm Rec Menu Set the text event as On 17 1 4 Setting at Normal Rec menu...

Страница 110: ...ext level is to show the channel name and text event status and channel number So in order to view text data press the Help button once at both the monitoring and playback modes 17 2 Using Keyboard In...

Страница 111: ...n immediately for further instruction Wren may issue a call tag to retrieve damaged merchandise Collect Freight Customer is responsible for taking appropriate action with carrier RETURNS In order to r...

Страница 112: ...ons wrenassociates com Wren and the Wren logo are trademarks of Wren Associates Ltd All other trademarks and or registered trademarks mentioned herein are properties of their respective owners and are...

Отзывы: