MODÈLE /
MODEL
BHV401S, BHV751S
BTR400S, BTR750S
MANUEL D’UTILISATION
INSTRUCTIONS FOR USE
POMPE SUBMERSIBLE ÉLECTRIQUE
ELECTRIC SUBMERSIBLE PUMP
FR / GB
MU_03GMP_SUMO_FR_GB
V281209
Страница 1: ...MOD LE MODEL BHV401S BHV751S BTR400S BTR750S MANUEL D UTILISATION INSTRUCTIONS FOR USE POMPE SUBMERSIBLE LECTRIQUE ELECTRIC SUBMERSIBLE PUMP FR GB MU_03GMP_SUMO_FR_GB V281209...
Страница 2: ...n diff rente de celle pr conis e dans la notice peut entra ner une d faillance de l appareil ou des blessures graves Veuillez conserver cette notice avec l quipement ou dans un endroit facilement acce...
Страница 3: ...s Toujours tre conscient du risque d ACCIDENTS lectrique SP CIFICATIONS BHV401S BHV751S BTR400S BTR750S D bit maximum L min 250 L min 325 L min 220 L min 300 L min D bit maximum m3 min 0 25 m3 min 0 3...
Страница 4: ...4 FR DIMENSIONS BHV401S BHV751S BHV401S BHV751S BTR400S BTR750S BTR400S A 50 mm B 324 mm C 340 mm BTR750S A 50 mm B 368 mm C 384 mm...
Страница 5: ...8 10 12 0 25 0 2 0 15 0 1 0 05 HMT m D bit m3 min BHV401S BHV751S D bit m3 min 0 1 5 10 15 0 2 0 3 HMT m BHV751S BTR400S 2 4 6 8 10 12 0 25 0 2 0 15 0 1 0 05 HMT m D bit m3 min BTR400S BTR750S D bit...
Страница 6: ...le fil de terre la tuyauterie des sanitaires V rifier que la prise de terre est suffisante pour l utilisation d un disjoncteur diff rentiel 4 Ne jamais tirer la pompe par son c ble d alimentation car...
Страница 7: ...Si une personne est dans l eau lorsque la pompe est immerg e ne jamais d marrer la pompe Aucune personne ou animal ne doivent se situer dans le bassin piscine bac lorsque la pompe est en fonctionnemen...
Страница 8: ...garniture pi ce d usure quand l huile contient trop d eau c est dire fortement mulsionn es laiteux ou quand le logement de l huile contient de l huile et de l eau Remplir avec l huile de turbine avec...
Страница 9: ...limentation V rification des connecteurs Le moteur est br l ou bien les isolements sont mauvais Remplacement du moteur La turbine est bloqu e par un corps tranger Nettoyer la cr pine et la turbine qui...
Страница 10: ...billes sup rieur 64 Roulement bille inf rieur 68 Porte roulement 71 Carter stator 75 Protection moteur 82 Condensateur 84 Fil d alimentation 85 Fil de terre 92 Entretoise 97 Rondelle ondul e 132 Garn...
Страница 11: ...84 Fil d alimentation 85 Fil de terre 92 Entretoise 97 Rondelle ondul e 132 Garniture m canique 133 Joint huile 138 Bouchon de remplissage 147 Support joint 156 Couvercle arri re 160 Turbine 50 Hz Tur...
Страница 12: ...the following 1 Model is that which you ordered 2 There is no damage in transit 3 Accessories are all supplied FOR SAFETY REASON PLEASE READ CAREFULLY THESE INSTRUCTIONS BEFORE USING THE PUMP IMPROPER...
Страница 13: ...f of each fluctuation ranges 4 The pump can not be used in explosive or flammable environments or with flammable liquids ALWAYS BE AWARE OF THE RISK OF ELECTRICAL ACCIDENTS SPECIFICATIONS BHV401S BHV7...
Страница 14: ...14 GB DIMENSIONS BHV401S BHV751S BHV401S BHV751S BTR400S BTR750S BTR400S A 50 mm B 324 mm C 340 mm BTR750S A 50 mm B 368 mm C 384 mm...
Страница 15: ...8 10 12 0 25 0 2 0 15 0 1 0 05 HMT m D bit m3 min BHV401S BHV751S D bit m3 min 0 1 5 10 15 0 2 0 3 HMT m BHV751S BTR400S 2 4 6 8 10 12 0 25 0 2 0 15 0 1 0 05 HMT m D bit m3 min BTR400S BTR750S D bit...
Страница 16: ...n delivery hoses or piping as this may cause reduced flow 6 Never install the pump directly on a weak soil layer or muddy ground or the pump may sink and soil or mud may enter the pump and or piping r...
Страница 17: ...ld be checked every 1 000 Hrs or three months and replaced every 2 000 Hrs or six months Change the oil and the shaft seal an article of consumption when the oil contains too much water i e heavily em...
Страница 18: ...nt or the motor s insulation is degraded Replace the motor The impeller is choked with foreign matter Clean strainer and impeller and provide with screen collector or catcher outside of the pump s str...
Страница 19: ...Rotor 62 Stator 63 Ball bearing Upper 64 Ball bearing Lower 68 Bearing housing 71 Stator casing 75 Motor protector 82 Capacitor Single phase 84 Lead wire 85 Earth wire 92 Spacer 97 Wave washer 132 Sh...
Страница 20: ...tor 82 Capacitor Single phase 84 Lead wire 85 Earth wire 92 Spacer 97 Wave washer 132 Shaft seal Mechanical seal 133 Oil seal 138 Oil plug 147 Seal bracket 156 Rear cover 160 Suction plate Impeller 60...
Страница 21: ...21 GB...
Страница 22: ...22 GB...
Страница 23: ...t exigible pour le r f rentiel NF EN 55014 2 ao t 1997 A1 avril 2002 A2 janvier 2009 EC DECLARATION OF CONFORMITY Manufacturer WORMS ENTREPRISES Parc Gustave Eiffel 1 Bd de Strasbourg Bussy Saint Geor...
Страница 24: ...Marne la Vall e Cedex 3 FRANCE Service Commercial Commercial service TEL 33 01 64 76 29 60 FAX 33 01 64 76 29 99 Services Pi ce de Rechange et SAV Spare parts and after sales services TEL 33 01 64 76...