INSTRUCTIONS FOR USE

GENERATORS

EN

MODELS

 

SILENTSTAR

6000D M YN

6500D T YN

Édition : 20190903

MU_02GE_SILENTSTAR_6000D_6500D_EN

Содержание SILENTSTAR 6000D M YN

Страница 1: ...INSTRUCTIONS FOR USE GENERATORS EN MODELS SILENTSTAR 6000D M YN 6500D T YN Édition 20190903 MU_02GE_SILENTSTAR_6000D_6500D_EN ...

Страница 2: ...or the user Indicates a strong possibility of severe personal injury loss of life and equipment damage if instructions are not followed CAUTION Indicates a possibility of personal injury or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions about the generator consult an authorized dealer or service shop The gener...

Страница 3: ... 4 CONTROL PANEL PAGE 9 5 PRE OPERATION CHECK PAGE 10 6 OPERATING PROCEDURES PAGE 13 7 STOPPING THE GENERATOR PAGE 15 8 OIL SENSOR PAGE 16 9 WATTAGE INFORMATION PAGE 16 10 MAINTENANCE SCHEDULE PAGE 17 11 HOW TO MAINTENANCE PAGE 18 12 PREPARATION FOR STORAGE PAGE 20 13 TROUBLESHOOTING PAGE 21 ...

Страница 4: ... products and this instruction manual Read the operator s instruction manual Stay clear of the hot surface Exhaust gas is poisonous Do not operate in an unventilated room Stop the engine before refueling Fire naked flame and smoking prohibited Caution risk of electric shock Do not connect the generator to the commercial power lines ...

Страница 5: ...ve polarity U r Rated voltage V Minus negative polarity T max Maximum ambient tempera ture C STOP position of a bistable push control COS ϕ Rated power factor ON position of a bistable push control I r Rated current A Protective earth ground m Mass kg Fuse Engine oil Add oil Battery charging condition Choke cold starting aid Engine start Electric start Engine stop Electric start Fuel Fast Slow ...

Страница 6: ...erator has a built in forced air cooling system and may become overheated if it is enclosed If generator has been covered to protect it from the weather during non use be sure to remove it and keep it well away from the area during generator use Operate the generator on a level surface It is not necessary to prepare a special foundation for the generator However the generator will vibrate on an ir...

Страница 7: ...ly hot during and for some time after operation Keep combustible materials well away from generator area Be very careful not to touch any parts of the hot engine especially the muffler area or serious burns may result Keep children and all bystanders at a safe distance from work areas It is absolutely essential that you know the safe and proper use of the power tool or appliance that you intend to...

Страница 8: ...UKO 1 1 Single socket 230V IP44 16 A 1 1 Single socket 230V 32A CEE 1 Three socket 400V 3P T N 16A 1 Voltmeter Serial Frequencymeter Serial Hourmeter Serial ENGINE Engine Model L100AE YANMAR Engine Type 4 stroke DIESEL Cooling System Air cooled Maximum Output 8 8 HP 3000 rpm Piston Displacement 435 cm3 Fuel Diesel Fuel Tank Capacity 22 L Autonomy at 3 4 Load 14 h 20 Starting System Electric Electr...

Страница 9: ...ker 7 Single phase socket 230 V 10 16 A SCHUKO 2 Voltmeter 8 Single phase socket 230 V 16 A CEE 3 Hourmeter 9 Single phase socket 230 V 32 A CEE or Three phase socket 400 V 3P T N 16 A 4 Frequencymeter 10 Earth connection 5 Emergency Stop 11 Connection for additional options 6 Key Switch ...

Страница 10: ...pacity Upper Level SILENTSTAR 6000D MYN 1 6 L SILENTSTAR 6000D TYN 1 6 L Change oil if contaminated See How To Maintenance RECOMMENDED ENGINE OIL Use class SE API classification oil or a higher grade oil according to the table below SAE 10W 30 is recommended for general all temperature use If single viscosity oil is used select the appropriate viscosity for the average temperature in your area Do ...

Страница 11: ...on the fuel filter neck before filling the tank Make sure the fuel filter is filled If not enough inside the filter it is necessary to drain the air Fuel tank capacity see page 8 PROCEDURE TO DRAIN AIR FROM THE HOSES After a first starting process or after a engine failure due to a lack of Diesel it is necessary to drain air from the fuel hoses between the tank and the injection pump before starti...

Страница 12: ...dous materials Keep generator at least 3 feet 1 meter away from buildings or other structures Only operate generator in a dry well ventilated area Keep exhaust pipe clear of foreign objects Keep generator away from naked flame No smoking Keep generator on a stable and level surface Do not block generator air vents with paper or other material GROUNDING THE GENERATOR Before using the generator the ...

Страница 13: ...n in the manual user book Turn the key in ON position During this time the display turns on see below the description of the display Press START button to start the engine and let it run for few minutes with no load 1 3 4 2 FONCTION DESCRIPTION 1 START button In manual mode press to start the generator 2 AUTO button Press to change to automatic mode 3 OFF RESET button Press to stop the generator w...

Страница 14: ...e user Hereunder several options are visible on the display during the working time 3000 RPM 230 V 50 Hz 16 2 h 13 8 V Speed of the engine Voltage of the generator Frequency of the generator Working Time of the engine Battery Voltage 6 3 USING ELECTRIC POWER AC APPLICATION This generator is thoroughly tested and adjusted in the factory If the generator does not produce the specified voltage consul...

Страница 15: ...ive Stop the generator immediately check the appliance and or generator for overloading or detect and have repaired as necessary by Worms dealer or service shop 7 STOPPING THE GENERATOR 1 Turn off the power switch of the electric equipment and unplug the cord from the receptacle of the generator 2 Allow the engine about 3 minutes to cool down at no load before stopping 3 Press the OFF RESET button...

Страница 16: ...e indicated wattage during start up Electrical motors require a large starting current Power requirements depend on the type of motor and its use Once enough surge is attained to start the motor the appliance will require only 30 to 50 of the wattage to continue running Most electrical tools require 1 2 to 3 times their wattage for running under load during use For example a 5 000 watt generator c...

Страница 17: ...2V 15V 18V 2 0 14 17 37 0 26 0 952 1V 3V 5V 8V 10V 12V 15V 3 5 12 à 10 23 45 0 32 0 517 1 5V 2 5V 4V 5V 6 5V 7 5V 3 5 10 à 8 35 70 0 32 0 332 1V 2V 2 5V 3 5V 4V 5V 10 MAINTENANCE SCHEDULE Daily 8 h Check all components according to PRE OPERATING CHECKS Check and refill Diesel and engine oil Every 50 h Wash air cleaner foam element more often if used in dirty or dusty environments Check the conditi...

Страница 18: ...ns will give you more detailed instructions on proper disposal 11 HOW TO MAINTENANCE 11 1 ENGINE OIL CHANGE Change engine oil every 200 hours for new engine change oil after 50 hours Open the hatch of the generator Drain oil by removing the drain plug and the oil filter cap while the engine is warm Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil fi...

Страница 19: ... hours PAPER ELEMENT Clean by tapping gently to remove dirt and blow off dust Never use oil Clean or replace the paper element every 50 hours of operation and replace element set every 200 hours Clean and replace air cleaner elements more often when operating in dusty environments AIR FILTER URETHANE FOAM CLEANING Remove the element wash and clean the urethane foam in kerosene Saturate in a mixtur...

Страница 20: ...refully by disconnecting the fuel line Diesel left in the fuel tank will eventually deteriorate making engine starting difficult Close the fuel cock before storage Change engine oil Check for loose bolts and screws tighten them if necessary Clean generator thoroughly with oiled cloth Spray with preservative if available NEVER USE WATER TO CLEAN YOUR GENERATOR Store generator in a well ventilated l...

Страница 21: ...s in the good position Turn the key switch to ON position Check to make sure generator is not connected to an appliance If connected turn off the power switch on the connected appliance and unplug WHEN NO ELECTRICITY IS GENERATED AT RECEPTACLE Check to make sure no fuse breaker is in the l ON position After making sure that the total wattage of the electrical appliance is within permissible limits...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...N Siège social Head Office ZAC de Lamirault 39 rue de Lamirault 77090 Collégien FRANCE TEL 33 0 1 64 76 29 50 FAX 33 0 1 64 76 29 99 Service SAV et Garantie After Sales and Waranty Service TEL 33 0 1 64 76 29 80 FAX 33 0 1 64 76 29 88 ...