7
4. PREPARING THE PUMP FOR OPERATION
4-1. CONNECT THE SUCTION PIPE TO THE PUMP
Use the appropriate tools to make the connection.
If the pump set is pumping water containing solids, ii is
necessary to use a strainer connected to the suction pipe.
These foreign bodies can damage the pump if they are sucked
into the pump casing.
4-2. CONNECTER THE DELIVERY HOSE TO THE PUMP
Use the appropriate tools to make the connection.
4-3. CHECK THE ENGINE OIL LEVEL
Place the pump set on a horizontal flat surface and fill the engine sump until you achieve
the maximum level on the dipstick (approximately 0,6 litre).
- Use an engine oil with a viscosity de 10 W 30 for ambient temperature between -15°C
to + 35°C
- If the conditions of use should exceed these limits, please contact WORMS
ENTREPRISES concerning the correct type of oil to use.
- Oil of an inferior quality or a lack of oil can cause serious engine damage and reduce
the expected engine life time.
Use only engine oil designed for petrol engines.
Never use engine oil designed for diesel engines.
To check the correct oil level, simply position the dipstick in the
tapped hole without screwing it into position.
4-4. FILLING THE ENGINE FUEL TANK
- Use unleaded automotive gasoline.
- The fuel should be new and free for foreign particles. The fuel should be transported
in containers designed for unleaded automotive gasoline. If this is not the case, the
Содержание Robin Subaru P 52 EX
Страница 1: ...INSTRUCTIONS FOR USE PUMP MODEL P 52 EX FR MU_P52EX_GB...
Страница 15: ...15...