34
TP 36 H / TP 65 H / TP 110 H
1. Unscrew and remove the oil filling dipstick plug [(b) Fig. 03].
2. To check the oil level, clean the dipstick plug gauge, using a clean cloth and fit the oil plug back.
Do not screw it to check the oil level.
3. If the oil level is less than the bottom level [(d) Fig. 05], fill the oil sump with correct oil [Fig. 07]
up to the top mark [(c) Fig. 05].
Oil capacity (Top level)
JARD 7 H OHV
0,08 L
TP 36 H
0,56 L
TP 65 H
0,6 L
TP 110 H
1,1 L
NOTE
Replace the oil as soon as it is contaminated (see the MAINTENANCE INSTRUCTIONS).
RECOMMENDED ENGINE FUEL
Prefer using an SE class (API classification) equivalent oil or an upper grade oil.
We recommend using SAE 10W-30 oils, for general use and all temperatures. If you use a single
grade oil, select the correct viscosity for an average ambient temperature, depending on the season.
[Fig. 07]
3.3. OIL SENSOR SECURITY
•
The oil sensor security controls the oil level in the carter and automatically stops the engine if the
oil level is less than a pre defined level.
•
This device is not existing for the models JARD 7 H OHV.
3.4. CHECK FUEL LEVEL (GASOLINE)
■
Never open the fuel tank cap when the engine is running or still hot.
■
Never fill the tank when the engine is running or still hot.
■
Do not refuel while smoking or near naked flame or other such potential fire hazards. Otherwise
fire accident may occur.
WARNING
□
Always fill up the tank in the open air.
□
Do not overfill the tank. Leave enough space so that the fuel can evaporate.