1.  Remove screw and wiring cover.

2.  Wire the incoming power to terminals 

R(L1) S (L2) T (L3).

3.  For single phase input applications use 

R(L1) and T (L3).

4.  Wire the motor to terminals U, V, W.

5.  Be sure to connect the incoming power and motor cabling ground conductors to the ground connections.

WDFC Quick Start Guide

Input Power and Motor Wiring

Control Input and Output Wiring Diagram

Содержание WorldDrive WDFC Series

Страница 1: ...pyright 2019 WorldWide Electric Corporation The Globe icon is a registered trademark of WorldWide Electric Corporation WORLDWIDEELECTRIC NET Quick Start Guide WORLDDRIVE WDFC This Quick Start Guide is...

Страница 2: ...or during operation Doing so may result in serious injury death or serious property damage Do not open the cover of the VFD even when the power supply to the VFD has been turned off unless it is nece...

Страница 3: ...emove screw and wiring cover 2 Wire the incoming power to terminals R L1 S L2 T L3 3 For single phase input applications use R L1 and T L3 4 Wire the motor to terminals U V W 5 Be sure to connect the...

Страница 4: ...Pump 6 Vacuum Pump 7 Constant Torq Sample Motor Nameplate EzStart N STP 0 0Hz 99 Start Easy Set 0 1 No Yes D C BAS10 60 50 Hz Sel 1 0 50 Hz 60 Hz DC EzStart N STP 0 0Hz DRV14 Motor Capacity 7 5 0 HP D...

Страница 5: ...e voltage Sample Motor Nameplate EzStart N STP 0 0Hz BAS13 Rated Curr 0 0 1000 0 A D 3 6 C 8 0 8 0 A EzStart N STP 0 0Hz BAS15 Rated Volt 170 480 V D 0 C 0 460V EzStart N STP 0 0Hz BAS11 Pole Number 2...

Страница 6: ...On the Keypad and monitor your Speed Hz 3 Select the Off Button to stop operation VERIFY MOTOR ROTATION DRV06 Cmd Source 1 Fx Rx 1 DC 2 Fx Rx 2 0 Keypad EzStart N STP 0 0Hz DRV07 Freq Ref Src EzStart...

Страница 7: ...A01 Bias 0 0 4 A01 Filter 5ms 6 A01 Monitor 0 0 7 AO2 Mode Frequency 8 A02 Gain 100 0 9 A02 Bias 0 0 10 A02 Filter 5ms 12 A02 Monitor 0 0 31 Relay 1 Trip 32 Relay 2 Run 33 Relay 3 None 34 Relay 4 None...

Страница 8: ...4 V2 5 I2 6 Int485 8 Fld Bus 0 0 11 DRV09 Control Mode 0 V F 1 Slip Comp 2 Resv 3 IM Sensorless 4 PM Sensorless V F 0 4 DRV14 Motor HP size capacity 5 800 DRV15 Torque Boost 0 Manual 1 Auto 2 Auto 2...

Страница 9: ...lean Mode 1 0 None 1 DI Dependent 2 Output Power 3 Output Current 0 AP2 16 Pump Clean Mode 2 0 None 1 Start 2 Stop 3 Start Stop 0 AP2 38 Decel Valve Freq in Hertz 40 00 AP2 39 Decel Valve Freq in seco...

Отзывы: