![Worldcast Systems Ecreso FM 100 W Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/worldcast-systems/ecreso-fm-100-w/ecreso-fm-100-w_user-manual_997881019.webp)
ECRESO FM 100/300 W, user manual– 06/2015
Page 19
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
www.worldcastsystems.com – [email protected]
3.
TECHNICAL SPECIFICATIONS
3.1.
Environmental
Nominal operating temperature
5°C to 45°C
Maximum operating temperature
0°C to 50°C
Warehousing temperature
-20°C to +70°C
Humidity
5 - 95 % non-condensing relative humidity
Altitude
Up to 3900 m
Warehousing time
< 10 years
Cooling Ecreso FM 100W / 300W
1 fan: between 10 l/s and 30 l/s depending on ambient temperature
3.2.
Power supply
Voltage
100 VAC to 254 VAC
Frequency
47 Hz - 63 Hz
Max consumption
200 W for the Ecreso FM 100W
500 W for the Ecreso FM 300W
Power factor
> 0.9
Fuses
10 AT
3.3.
Physical
Overall dimension
487.5 mm X 2U (89 mm) X 475 mm
Rack size without front panel
437.7 X 82 X 443.8 mm (WxHxD)
Enclosure depth required
600 mm
Mounting
19’’enclosure, with 4 M6X12 screws
Weight
Ecreso FM 100W
around 9 kg
Ecreso FM 300W
around 9.5 kg
3.4.
Interface panel
Indicators
Green LED: CPU activity
Red LED: major fault
Yellow LED: minor fault
Red LED: RF fault (3 dB)
Red LED: VSWR fault
Green LED: safety interlock
Green LED: RF on
Yellow LED: local mode